Output function normally open / normally closed programmable. Wide operating temperature range. Two-wire technology. High protection rating for the requirements of harsh industrial environments. Large operating voltage range
Electrical design
PNP/NPN
Output function
normally open / normally closed;(selectable)
Sensing range [mm]
15
Housing
threaded type
Dimensions [mm]
M30 x 1.5 / L = 81
Operating voltage [V]
10...55 DC
Protection class
II
Reverse polarity protection
yes
Outputs
Electrical design
PNP/NPN
Output function
normally open / normally closed;(selectable)
Max. voltage drop switching output DC [V]
4.6
Minimum load current [mA]
4
Max. leakage current [mA]
0.6
Permanent current rating of switching output DC [mA]
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — II5436-02 — 13.04.2023 —