Suited for use in mobile machines. Two switching outputs, one of which can be configured as diagnostic output. High shock and vibration resistance. Excellent EMC resistance
Number of inputs and outputs
Number of digital outputs: 2
Measuring range
-1...10 bar
-14.5...145 psi
-100...1000 kPa
-0.1...1 MPa
Process connection
threaded connection G 1/4 external thread internal thread:M5
Application
for mobile applications
Media
liquids and gases
Medium temperature [°C]
-25...90
Min. bursting pressure
150 bar
2175 psi
15 MPa
Pressure rating
75 bar
1087 psi
7.5 MPa
Type of pressure
relative pressure; vacuum
Operating voltage [V]
9.6...36 DC;(communication mode: 18...32)
Current consumption [mA]
< 45
Min. insulation resistance [MΩ]
100;(500 V DC)
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
0.3
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2
Outputs
Total number of outputs
2
Output signal
switching signal; IO-Link;(configurable)
Electrical design
PNP
Number of digital outputs
2
Output function
normally open / normally closed;(parameterisable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
250
Switching frequency DC [Hz]
170
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
Measuring/setting range
Measuring range
-1...10 bar
-14.5...145 psi
-100...1000 kPa
-0.1...1 MPa
Set point SP
-0.9...10 bar
-13...145 psi
-0.09...1 MPa
Reset point rP
-0.95...9.95 bar
-14...144 psi
-0.095...0.995 MPa
In steps of
0.05 bar
1 psi
0.005 MPa
Factory setting
SP1 = 2.50 bar
rP1 = 2.30 bar
SP2 = 7.50 bar
rP2 = 7.30 bar
OUT1 = Hno
OUT2 = Hno
Accuracy / deviations
Switch point accuracy [% of the span]
< ± 0,5
Repeatability [% of the span]
< ± 0,1;(with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS);(BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation [% of the span]
< ± 0,1
Long-term stability [% of the span]
< ± 0,1;(per year)
Temperature coefficient zero point [% of the span / 10 K]
< ± 0,2;(0...80 °C)
Temperature coefficient span [% of the span / 10 K]
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]
224
Materials
stainless steel (1.4301 / 304); FKM; EPDM/X; PA
Materials (wetted parts)
stainless steel (1.4305 / 303); ceramics; FKM
Min. pressure cycles
100 million
Process connection
threaded connection G 1/4 external thread internal thread:M5
Restrictor element integrated
no (can be retrofitted)
Displays / operating elements
Display
operation
2 x LED, green
switching status
2 x LED, yellow
Teach function
yes
Remarks
with reference to UL: "limited voltage" with overcurrent protection in accordance with UL508
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; coding: A
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PP004E-00 — 13.04.2023 —