< 170;(mean value at 24 VDC; peak current pulsed: <350)
Power consumption [W]
4
Protection class
III
Type of light
infrared light
Wave length [nm]
850
Image sensor
PMD 3D ToF-Chip
Internal lighting
yes;(infrared: 850 nm invisible radiation)
Detection zone
Operating distance [mm]
50...3000
Note on operating distance
object size: 200 x 200 mm
reflectivity: 18 %
Image resolution 3D [px]
224 x 172
Angle of aperture 3D [°]
58 x 44
Max. reading rate[Hz]
20
Measuring/setting range
Measuring range [m]
< 30;(depending on settings, object size, and reflectivity)
Software / programming
Parameter setting options
via PC with ifm Vision Assistant or XML-RPC
Interfaces
Communication interface
Ethernet
Usage type
parameter setting; data transmission
Ethernet
Number of Ethernet interfaces
1
Transmission standard
10Base-T; 100Base-TX
Transmission rate
10; 100
Protocol
TCP/IP
Factory settings
IP address: 192.168.0.69
subnet mask: 255.255.255.0
gateway IP address: 192.168.0.201
Operating conditions
Ambient temperature [°C]
-10...40
Note on ambient temperature
Housing: < 45° C
see operating instructions
Storage temperature [°C]
-40...85
Protection
IP 50
Max. immunity to extraneous light [klx]
8
Tests / approvals
EMC
DIN EN IEC 61000-6-4
radiation of interference
DIN EN IEC 61000-6-2
immunity / industrial environments
Shock resistance
DIN EN 60068-2-27
50 g / (11 ms) not repetitive
DIN EN 60068-2-27
40 g / (6 ms) repetitive
Vibration resistance
DIN EN 60068-2-6
2 g / (10...150 Hz)
DIN EN 60068-2-64
2.3 g RMS / (10...500 Hz)
Laser protection class
1
Notes on laser protection
Caution:
invisible laser radiation
laser class:
1
IEC 60825-1:2014
Complies with 21 CFR 1040.10 except for conformance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56, dated May 8, 2019.
Electrical protection
DIN EN IEC 61010-2-201
electrical supply only via PELV circuits
Weight [g]
241.1
Dimensions [mm]
80 x 43.5 x 21
Materials
housing: diecast zinc; front pane Illu: PMMA
Pack quantity
1 pcs.
Electrical connection
Cable: 1 m, PVC
Electrical connection - Ethernet RJ45 connector
RJ45_Steckverbinder
Connector: 1 x RJ45
Other data
Field of view size
without lens distortion correction
measuring range / distance [m]
Length [m]
Width [m]
0.50
0.50
0.40
1.00
1.10
0.80
1.50
1.60
1.20
2.00
2.20
1.70
2.50
2.70
2.10
3.00
3.30
2.50
Repeatability
measuring range / distance [m]
Exposure time [µs]
Repeatability
accuracy [mm]
Measured distance values (1 Sigma) on grey objects
reflectivity 18 % [mm]
0.1...0.25
200
± 4
± 5
0.25...0.5
400
± 4
± 5
0.5...1
1000
± 6
± 10
1...2
2000
± 12
± 20
2...3
2000
± 50
± 40
Repeatability
referred to
distance measurement of an individual pixel
Measured at
centre of image with median filter
Ambient temperature
20° C
Temperature drift
-10...+40° C[mm/K]
0.2
Relative accuracy
typical
± 4
measured at a reflectivity of 18% to 90%
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — O3X120-01 — 27.07.2023 —