ifm Electronic
Regular price
€708,50
Regular price
Sale price
€708,50
Unit price
/
per
Sale
Sold out
Taxes included.
📦 Ready for dispatch: 03.12.2025
Couldn't load pickup availability
Refresh
SKU: SKU: PI1009
Robust stainless steel design for the requirements of the food and beverage industry.
Hygienic, flush design.
Resistant to high-pressure cleaning with aggressive cleaning agents.
High temperature resistance and high protection rating.
Programmable analogue and switching output
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
-1000...1000 mbar
-14.5...14.5 psi
-401...401 inH2O
-100...100 kPa
Process connection
threaded connection S30x2 external thread Aseptoflex
Special feature
Gold-plated contacts
Application
flush mountable for the food and beverage industry
Media
viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]
-25...150
Min. bursting pressure
30000 mbar
435 psi
3000 kPa
Pressure rating
10000 mbar
145 psi
1000 kPa
Vacuum resistance [mbar]
-1000
Type of pressure
relative pressure; vacuum
No dead space
yes
Min. insulation resistance [MΩ]
100;(500 V DC)
Protection class
III
Reverse polarity protection
yes
Integrated watchdog
yes
2-wire
Operating voltage [V]
20...30 DC
Current consumption [mA]
3.5...21.5
Power-on delay time [s]
< 1
3-wire
Operating voltage [V]
18...30 DC
Current consumption [mA]
5...45;(430 bei max. Laststrom)
Power-on delay time [s]
< 0.5
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs
2
Output signal
switching signal; analogue signal; IO-Link
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed;(parameterisable)
Number of analogue outputs
1
Analogue current output [mA]
4...20, invertible; (scalable)
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
3-wire
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
100
Switching frequency DC [Hz]
125
Max. load [Ω]
(Ub - 10 V) / 21,5 mA; 650Ω (Ub = 24 V)
Measuring/setting range
Measuring range
-1000...1000 mbar
-14.5...14.5 psi
-401...401 inH2O
-100...100 kPa
Set point SP
-997...1000 mbar
-14.46...14.5 psi
-400...401 inH2O
-4.9...100 kPa
Reset point rP
-1000...997 mbar
-14.5...14.46 psi
-401...400 inH2O
-100...99.7 kPa
Analogue start point
-1000...599 mbar
-14.5...8.68 psi
-401...240 inH2O
-100...59.9 kPa
Analogue end point
-599...1000 mbar
-8.68...14.5 psi
-240...401 inH2O
-59.9...100 kPa
Min. difference between SP and rP
3 mbar
0.05 psi
2 inH2O
0.3 kPa
In steps of
1 mbar
0.01 psi
1 inH2O
0.1 kPa
Factory setting
SP1 = 250 mbar
rP1 = 230 mbar
SP2 = 750 mbar
rP2 = 730 mbar
ASP = 0 mbar
AEP = 1000 mbar
dAP = 2.00 s
dAA =2.00 s
Temperature monitoring
Measuring range
-25...150 °C
-13...302 °F
Accuracy / deviations
Switch point accuracy [% of the span]
< ± 0,2;(DIN EN IEC 62828-1; Turn down 1:1)
Repeatability [% of the span]
< ± 0,1;(with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]
< ± 0,2;(DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Linearity deviation [% of the span]
< ± 0,15;(Turn down 1:1)
Hysteresis deviation [% of the span]
< ± 0,15;(Turn down 1:1)
Long-term stability [% of the span]
< ± 0,1;(Turn down 1:1; per year)
Total deviation over temperature range
Temperature range
total deviation
-25...15 °C
Characteristics deviation ± 0,05 % of the span / 10 K
15...80 °C
Characteristics deviation
80...150 °C
Characteristics deviation ± 0,1 % of the span / 10 K
Notes on the accuracy / deviation
for further details see section Diagrams and graphs
Temperature monitoring
Accuracy [K]
± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur ))
Repeatability [K]
± 0,2
Resolution [K]
0.2
Response times
Damping process value dAP [s]
0...99.99
Damping for the analogue output dAA [s]
0...99.99
2-wire
Step response time analogue output [ms]
30
3-wire
Min. response time of switching output (dAP) [ms]
3
Step response time analogue output [ms]
7
Temperature monitoring
Dynamic response T05 / T09 [s]
< 35 / < 135;(DIN EN 60751 water ; > 0,9 m/s)
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A)
SIO mode
yes
Required master port type
A
Min. process cycle time [ms]
5.6
IO-Link resolution pressure [mbar]
0.1
IO-Link resolution temperature [K]
0.2
IO-Link process data (cyclical)
function
bit length
pressure
32
temperature
32
device status
4
binary switching information
2
IO-Link functions (acyclical)
application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter
Supported DeviceIDs
Type of operation
DeviceID
default
1151
Operating conditions
Ambient temperature [°C]
-25...80
Storage temperature [°C]
-40...100
Protection
IP 67; IP 68; IP 69K
Tests / approvals
EMC
Shock resistance
DIN EN 60068-2-27
50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6
20 g (10...2000 Hz)
MTTF [years]
201
Note on approval
factory certificate available as download at www.factory-certificate.ifm
UL approval
UL Approval no.
J048
File number UL
E174189
Weight [g]
348.8
Materials
stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Materials (wetted parts)
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE
Min. pressure cycles
100 million
Tightening torque [Nm]
25
Process connection
threaded connection S30x2 external thread Aseptoflex
Displays / operating elements
Display
Display unit
LED, green
switching status
LED, yellow
function display
alphanumeric display, 4-digit
measured values
alphanumeric display, 4-digit
Display unit
mbar; psi; kPa; inH2O
Notes
Please do not use for new projects.; no more adapters available as accessories
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
Diagrams and graphs
X
temperature
Y
total deviation
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PI1009-00 — 13.11.2023 —