Precise linear 0...10 V output signal. High repeatability and low linearity error. With long-term stability thanks to high overload protection. Robust stainless steel housing for use in harsh industrial environments. Wide operating temperature range
Number of inputs and outputs
Number of analogue outputs: 1
Measuring range
0...10 bar
0...145 psi
0...100 kPa
Process connection
threaded connection G 1/4 external thread (DIN EN ISO 1179-2)
Special feature
Gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Application
for industrial applications
Media
liquids and gases
Medium temperature [°C]
-25...90;(on request: -40...90 °C)
Min. bursting pressure
150 bar
2175 psi
15000 kPa
Pressure rating
75 bar
1087 psi
7500 kPa
Vacuum resistance [mbar]
-1000
Type of pressure
relative pressure
Operating voltage [V]
16...32 DC;(depends on lubrication, seal and pressure rating)
Current consumption [mA]
< 18
Min. insulation resistance [MΩ]
100;(500 V DC)
Protection class
III
Reverse polarity protection
yes
Inputs / outputs
Number of inputs and outputs
Number of analogue outputs: 1
Outputs
Total number of outputs
1
Output signal
analogue signal
Number of analogue outputs
1
Analogue voltage output [V]
0...10
Min. load resistance [Ω]
2000
Overload protection
yes
Measuring/setting range
Measuring range
0...10 bar
0...145 psi
0...100 kPa
Accuracy / deviations
Repeatability [% of the span]
< 0,1;(with temperature fluctuations < 10 K)
Characteristics deviation [% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS);(BFSL = Best Fit Straight Line; LS = limit value setting)
Long-term stability [% of the span]
< ± 0,05;(per 6 months)
Temperature coefficient zero point [% of the span / 10 K]
0,45;(0...80 °C)
Temperature coefficient span [% of the span / 10 K]
0,2;(0...80 °C)
Response times
Step response time analogue output [ms]
3
Operating conditions
Ambient temperature [°C]
-25...80
Storage temperature [°C]
-40...100
Protection
IP 68; IP 69K
Tests / approvals
EMC
EN 61000-4-2 ESD
4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated
30 V/m
EN 61000-4-4 Burst
2 kV
EN 61000-4-6 HF conducted
10 V
radiation of interference
according to the automotive directive 2004/104/EC
CISPR 25
immunity
according to the automotive directive 2004/104/EC
ISO 11452-2 HF radiated
100 V/m
ISO 7637-2 pulse
severity level 4
Shock resistance
DIN EN 60068-2-27
50 g (11 ms)
DIN EN 61373
category 3
Vibration resistance
DIN EN 60068-2-6
20 g (10...2000 Hz)
DIN EN 61373
category 2
MTTF [years]
550
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
25...35;(recommended tightening torque; depends on lubrication, seal and pressure rating)
Process connection
threaded connection G 1/4 external thread (DIN EN ISO 1179-2)
Process connection sealing
FKM (DIN EN ISO 1179-2)
Restrictor element integrated
no (can be retrofitted)
Notes
customer-specific
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PX9524-00 — 04.10.2017 —