Precise detection of flow in pipes. Suitable for water, oils and glycol solutions. Precise linearized analogue output. Robust housing with very high pressure rating. Lifespan of more than 10 million pressure cycles
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
5...240 gph
0.1...4 gpm
Process connection
threaded connection 3/4" NPT
Special feature
Gold-plated contacts
Application
for industrial applications
Media
Liquids; water; glycol solutions; coolants
Note on media
oil 1 with viscosity: 10 mm²/s (104 °F)
oil 2 with viscosity: 46 mm²/s (104 °F)
Medium temperature [°F]
14...212
Pressure rating [bar]
40
Pressure rating [MPa]
4
MAWP (for applications according to CRN) [bar]
40
Operating voltage [V]
18...30 DC;(to SELV/PELV)
Current consumption [mA]
< 50
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
< 3
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs
2
Output signal
switching signal; analogue signal; frequency signal; IO-Link;(configurable)
Number of digital outputs
2
Output function
normally open / normally closed;(parameterisable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
150;(per output 2 x 200 (...140 °F); 2 x 250 (...104 °F))
Switching cycles (mechanical)
10 million
Number of analogue outputs
1
Analogue current output [mA]
4...20
Max. load [Ω]
500
Short-circuit protection
yes
Overload protection
yes
Frequency of the output [Hz]
0...10000
Measuring/setting range
Measuring range
5...240 gph
0.1...4 gpm
Display range
0...288 gph
0...4.8 gpm
Resolution
1 gph
0.05 gpm
Set point SP
2...240 gph
0.05...4 gpm
Reset point rP
0...238 gph
0...3.95 gpm
Frequency end point, FEP
16...240 gph
0.25...4 gpm
In steps of
1 gph
0.05 gpm
Frequency at the end point FRP [Hz]
10...10000
Measuring dynamics
1:50
Temperature monitoring
Measuring range [°F]
14...212
Display range [°F]
-26...252
Resolution [°F]
2
Set point SP [°F]
16...212
Reset point rP [°F]
14...210
In steps of [°F]
2
Frequency start point, FSP [°F]
14...172
Frequency end point, FEP [°F]
54...212
Frequency at the end point FRP [Hz]
10...10000
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range)
± (4 % MW + 1 % MEW);(Q > 0,3 l/min; medium and operating temperature: +71,6 °F ± 4K)
Repeatability
± 1 % MEW
Temperature monitoring
Temperature drift
0,9802 °F / K
Accuracy [K]
3 K (77 °F; Q > 1 l/min)
Response times
Flow monitoring
Response time [s]
0.01
Damping process value dAP [s]
0...5
Damping for the analogue output dAA [s]
0...5
Temperature monitoring
Dynamic response T05 / T09 [s]
T09 = 120 (Q > 1 l/min)
Software / programming
Parameter setting options
hysteresis / window; normally open / normally closed; switching logic; current output; medium selection; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9 CDV
Profiles
Smart Sensor: Process Data Variable; Device Identification
SIO mode
yes
Required master port type
A
Process data analogue
2
Process data binary
2
Min. process cycle time [ms]
5
Supported DeviceIDs
Type of operation
DeviceID
default
565
Operating conditions
Ambient temperature [°F]
32...140
Note on ambient temperature
medium temperature < 176 °F
medium temperature < 212 °F: 32...104 °F
Storage temperature [°F]
5...176
Protection
IP 65; IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27
20 g (11 ms)
Vibration resistance
DIN EN 60068-2-6
5 g (10...2000 Hz)
MTTF [years]
145
UL approval
UL Approval no.
I005
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Connector: 1 x M12; coding: A; Contacts: gold-plated
Diagrams and graphs
Pressure loss
dP
Pressure loss
Q
volumetric flow quantity
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SBN232-01 — 13.04.2023 —