ifm Electronic

IFM SD0523 - Compressed air meter SDD11DGXFPKG/US-100

IFM SD0523 - Compressed air meter SDD11DGXFPKG/US-100

Regular price €10.000,00
Regular price Sale price €10.000,00
Sale Sold out
Taxes included.

📦 Ready for dispatch: 25.02.2026

SKU: SKU:SD0523

Precise measurement of flow, consumption and medium temperature.
High accuracy, repeatability and measurement dynamics.
For detecting compressed air in industrial use.
With switching output, analogue output and pulse output.
Adjustable to inside pipe diameters
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0.5...143.9 m/s 8...2110 m³/h 0.12...35.18 m³/min
Process connection threaded connection G 1 internal thread
Installation Adjustable to inside pipe diameters;(38...254 mm)
Media compressed air
Medium temperature [°C] 0...60
Pressure rating [bar] 16
Pressure rating [MPa] 1.6
Pressure rating [psi] 232
MAWP (for applications according to CRN) [bar] 16
Operating voltage [V] 18...30 DC;(to SELV/PELV)
Current consumption [mA] < 110
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; pulse signal; IO-Link;(configurable)
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed;(parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250;(per output)
Number of analogue outputs 1
Analogue current output [mA] 4...20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range Measuring/setting range; Flow monitoring; The values apply at: Ø 72 mm
Measuring range
0.5...143.9 m/s 8...2110 m³/h 0.12...35.18 m³/min
Display range
0...172.7 m/s 0...2532 m³/h 0...42.22 m³/min
Resolution
0.1 m/s 2 m³/h 0.02 m³/min
Set point SP
1.2...143.9 m/s 18...2110 m³/h 0.28...35.18 m³/min
Reset point rP
0.5...143.2 m/s 6...2100 m³/h 0.12...35 m³/min
Analogue start point ASP
0...107.9 m/s 0...1582 m³/h 0...26.38 m³/min
Analogue end point AEP
36...143.9 m/s 528...2110 m³/h 8.8...35.18 m³/min
In steps of
0.1 m/s 2 m³/h 0.02 m³/min
Volumetric flow quantity monitoring
Pulse value 1...1000 x 10³
In steps of 1 Nm³
Pulse length [s] 0,7...2 (D = 72 mm)
Temperature monitoring
Measuring range [°C] 0...60
Display range [°C] -12...72
Resolution [°C] 0.2
Set point SP [°C] 0.4...60
Reset point rP [°C] 0.2...59.8
Analogue start point [°C] 0...45
Analogue end point [°C] 15...60
In steps of [°C] 0.2
Accuracy / deviations
Flow monitoring
Repeatability [% of the measured value] ± 1,5
Accuracy (in the measuring range) ± (6 % MW + 0,6 % MEW);(D = 72mm, T = 22 °C; standard volume flow: 50...850 Nm³/h)
Temperature monitoring
Accuracy [K] ± 2,5 (Q > 2 Nm³/h)
Response times
Flow monitoring
Response time [s] 0.1;(dAP = 0)
Damping process value dAP in steps [s] 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Temperature monitoring
Dynamic response T05 / T09 [s] 30 (Q > 2 Nm³/h)
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification
SIO mode yes
Required master port type A
Process data analogue 3
Process data binary 2
Min. process cycle time [ms] 5
Supported DeviceIDs
Type of operation DeviceID
default 381
Operating conditions
Ambient temperature [°C] 0...60
Storage temperature [°C] -20...85
Max. relative air humidity [%] 90
Protection IP 65
Tests / approvals
EMC
DIN EN 60947-5-9
DIN EN 61000-6-3
Vibration resistance
DIN EN 60068-2-6 5 g (55...2000 Hz)
MTTF [years] 213
Weight [g] 539.5
Materials PBT-GF20; PC; stainless steel (1.4301 / 304); FKM
Materials (wetted parts) stainless steel (316 / 1.4401); stainless steel (1.4301 / 304); ceramics glass passivated; PEEK; polyester; FKM
Process connection threaded connection G 1 internal thread
Displays / operating elements
Display
Display unit 4 x LED, green (Nm³/min, Nm³/h, Nm³, °C)
function display 1 x LED, green
switching status 2 x LED, yellow
measured values alphanumeric display, 4-digit
programming alphanumeric display, 4-digit
Remarks
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
D = inside pipe diameter
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Diagrams and graphs
final value of the measuring range referred to the internal pipe diameter
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SD0523-01 — 13.04.2023 —