Skip to product information
1 of 1

ifm Electronic

IFM SD0550 - Compressed air meter SDR14DGXFPKG/US-100

IFM SD0550 - Compressed air meter SDR14DGXFPKG/US-100

Regular price €10.000,00
Regular price Sale price €10.000,00
Sale Sold out
Taxes included.

📦 Ready for dispatch: 25.02.2026

SKU: SKU:SD0550

Precise measurement of flow, consumption and medium temperature.
High accuracy, repeatability and measurement dynamics.
For detecting compressed air in industrial use.
With switching output, analogue output and pulse output.
Clearly visible 4-digit LED display
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
1...250 l/min 0.3...82.9 m/s 0.04...15 m³/h
Process connection threaded connection G 1/4 DN8
Application for industrial applications
Media air
Medium temperature [°C] 0...40
Pressure rating [bar] 2
Operating voltage [V] 18...30 DC;(to SELV/PELV)
Current consumption [mA] < 110
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 1
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Output signal switching signal; analogue signal; pulse signal; IO-Link;(configurable)
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed;(parameterisable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 250;(per output)
Number of analogue outputs 1
Analogue current output [mA] 4...20; (scalable)
Max. load [Ω] 500
Pulse output consumed quantity meter
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Measuring/setting range
Measuring range
1...250 l/min 0.3...82.9 m/s 0.04...15 m³/h
Display range
0...300 l/min 0...99.5 m/s 0...18 m³/h
Set point SP
2...250 l/min 0.7...82.9 m/s 0.12...15 m³/h
Reset point rP
1...249 l/min 0.3...82.5 m/s 0.04...14.92 m³/h
Analogue start point ASP
0...187.5 l/min 0...62.2 m/s 0...11.26 m³/h
Analogue end point AEP
62.5...250 l/min 20.7...82.9 m/s 3.74...15 m³/h
In steps of
0.5 l/min 0.1 m/s 0.02 m³/h
Volumetric flow quantity monitoring
Pulse value 0.001...1000000 m³
In steps of 0.001 m³
Pulse length [s] 0,1...2
Temperature monitoring
Measuring range [°C] 0...60
Display range [°C] -12...72
Accuracy / deviations
Flow monitoring
Repeatability [% of the measured value] ± 1,5
Accuracy (in the measuring range) ± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW);(class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN8)
Temperature monitoring
Accuracy [K] ± 2;(medium flow in the limit area of the flow measurement range)
Response times
Flow monitoring
Response time [s] 0.1;(dAP = 0)
Damping process value dAP in steps [s] 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9 CDV
Profiles no profile
SIO mode yes
Required master port type A
Process data analogue 3
Process data binary 2
Min. process cycle time [ms] 4.1
Supported DeviceIDs
Type of operation DeviceID
default 1329
Operating conditions
Ambient temperature [°C] 0...40
Storage temperature [°C] -20...85
Max. relative air humidity [%] 90
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Vibration resistance
DIN EN 68000-2-6 5 g (55...2000 Hz)
MTTF [years] 220
UL approval
File number UL E174189
Pressure Equipment Directive Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g] 955.8
Materials PBT-GF20; NBR; PC; stainless steel (1.4301 / 304); PTFE; brass coated; FKM; aluminium powder-coated
Materials (wetted parts) stainless steel (1.4301 / 304); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium; cyanoacrylate
Process connection threaded connection G 1/4 DN8
Length [mm] 182.3
Displays / operating elements
Display
Display unit 5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C)
function display 1 x LED, green
switching status 2 x LED, yellow
measured values alphanumeric display, 4-digit
programming alphanumeric display, 4-digit
Remarks
MW = measured value
MEW = Final value of the measuring range
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
For information about installation and operation please see the operating instructions.
Note: no medical device!
Permanent availability, safe switching-off or self-diagnosis function cannot be confirmed. The manufacturer of the machine/equipment is responsible for ensuring this, if required.
Notes customer-specific
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SD0550-00 — 23.11.2020 —
View full details