Precise measurement of flow and consumption.
High accuracy, repeatability and measurement dynamics.
For detecting compressed air in industrial use.
With switching output, analogue output and pulse output.
Clearly visible 4-digit LED display
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0.6...143.9 m/s
73...17480 m³/h
Process connection
flange DN200 DIN 2448 according to:DIN EN 10220
Application
for industrial applications
Media
compressed air
Medium temperature [°C]
-10...60
Min. bursting pressure [bar]
64
Min. bursting pressure [MPa]
6.4
Pressure rating [bar]
16
Pressure rating [MPa]
1.6
Operating voltage [V]
18...30 DC;(to SELV/PELV)
Current consumption [mA]
< 80
Protection class
III
Reverse polarity protection
yes
Power-on delay time [s]
1
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Inputs
Outputs
Output signal
switching signal; analogue signal; pulse signal; IO-Link;(configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed;(parameterisable)
Max. voltage drop switching output DC [V]
2.5
Permanent current rating of switching output DC [mA]
150;(per output)
Number of analogue outputs
1
Analogue current output [mA]
4...20; (scalable)
Max. load [Ω]
500
Pulse output
consumed quantity meter
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
Measuring/setting range
Measuring range
0.6...143.9 m/s
73...17480 m³/h
Display range
1.2...172.7 m/s
146...20976 m³/h
In steps of
Pressure monitoring
Measuring range [bar]
-1...16
Display range [bar]
-1...20
Resolution [bar]
0.05
Set point SP [bar]
-0.92...16
Reset point rP [bar]
-1...15.92
Analogue start point [bar]
-1...12.8
Analogue end point [bar]
2.2...16
In steps of [bar]
0.01
Volumetric flow quantity monitoring
Measuring range
0...100000000 m³
0...353146667.2 scf
Display range
0...100000000 m³
0...353146667.2 scf
Set point SP
0.001...10000000 m³
0.05...353146667.2 scf
Pulse value
0.001...10000000 m³
0.05...353146667.2 scf
In steps of
Pulse length [s]
0.002...2
Temperature monitoring
Measuring range
Display range
-24...74 °C
-11.2...165.2 °F
Resolution
Set point SP
-9.7...60 °C
14.6...140 °F
Reset point rP
-10...59.7 °C
14...139.4 °F
Analogue start point
-10...46 °C
14...114.8 °F
Analogue end point
In steps of
Accuracy / deviations
Accuracy (in the measuring range)
class 141: ± (3 % MW + 0,3 % MEW); class 344: ± (6 % MW + 0,6 % MEW) ; air quality to ISO 8573-1:2010; reference conditions: inlet pipe length>= 302 cm outlet pipe length>= 51 cm; reference temperature: 18..26 °C; standard volume flow 73...7896 m³/h; (standard volume flow DIN_ISO_2533 15 °C , 1013,25 mbar, 0 % r.H.)
Pressure monitoring
Repeatability [% of the final value]
± 0,2
Characteristics deviation [% of the final value]
< ± 0,5;(BFSL = Best Fit Straight Line)
Greatest TEMPCO of the span [% MEW / 10 K]
± 0,3
Greatest TEMPCO of the zero point [% MEW / 10 K]
± 0,1
Temperature monitoring
Accuracy [K]
± 0,5;(medium flow in the limit area of the flow measurement range)
Response times
Response time [s]
0.1;(dAP = 0)
Damping process value dAP [s]
0...5
Pressure monitoring
Response time [s]
0.05
Temperature monitoring
Dynamic response T05 / T09 [s]
T09 = 0,5
Software / programming
Parameter setting options
hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9 CDV
Profiles
Digital Measuring Sensor (0x800A), Identification and Diagnosis (0x4000)
SIO mode
yes
Required master port type
A
Process data analogue
8
Process data binary
2
Min. process cycle time [ms]
7.2
Supported DeviceIDs
Type of operation
DeviceID
default
1545
Operating conditions
Ambient temperature [°C]
0...60
Storage temperature [°C]
-20...85
Max. relative air humidity [%]
90
Protection
IP 65; IP 67
Tests / approvals
EMC
Vibration resistance
DIN EN 68000-2-6
5 g (10...2000 Hz)
MTTF [years]
167
Pressure Equipment Directive
Modul A; can be used for group 2 fluids; group 1 fluids on request
Weight [g]
37790
Materials
PBT+PC-GF30; PPS GF40; stainless steel (1.4301 / 304); stainless steel (1.4305 / 303); stainless steel (1.4404 / 316L); FKM
Materials (wetted parts)
stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate; pipe section: steel galvanised
Process connection
flange DN200 DIN 2448 according to:DIN EN 10220
Displays / operating elements
Display
colour display 1,44", 128 x 128 pixels
2 x LED, yellow
Remarks
MW = measured value
MEW = Final value of the measuring range
D = inside pipe diameter
Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.
For information about installation and operation please see the operating instructions.
Pack quantity
1 pcs.
Electrical connection
Connection
Connector: 1 x M12; coding: A
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SDG850-00 — 02.02.2022 —