Reliable protection of extensive hazardous areas. For use on conveyor belts. Robust design for use in harsh industrial environments. Easy setting of the rope tension. Use in zone 21/zone 22 hazardous areas
Application
zone 21 hazardous area; zone 22 hazardous area; food industry
Operating voltage [V]
250 AC/DC
Rated insulation voltage [V]
500
Outputs
Electrical design
snap-action contact; thermal current: 10 A
Output function
auxiliary contact
2 x normally open
safety contact
2 x normally closed
Contact rating
2,5 A
Short-circuit protection
no
Operating conditions
Ambient temperature [°C]
-25...60
Protection
IP 67; IP 69K
Tests / approvals
Shock resistance
15 g / 11 ms
Vibration resistance
IEC62-2-6
10-55 Hz / +1 Hz
Weight [g]
3447.2
Materials
housing: stainless steel (316 / 1.4401)
Information on service life
Switching cycles (mechanical):
> 1.000.000
Installation position
any
Rope span
125 m;(per side)
Activation force [N]
< 125;(tension force:130 N)
Electrical connection
Required protection
10 A; fast acting
Remarks
For information about installation and operation please see the operating instructions.
Ex-approved switch type LS-Ex:Ex d IIC T6 (-20 °C ≤ Ta ≤ 60 °C) Gb; Ex td IIIC T85 °C ( -20 °C ≤ Ta ≤ 60 °C) Db