1
/
of
1
Schmersal
Schmersal AZ201CC-T-1P2P Sicherheitsschalter mit Betätiger, sku: 103015814
Schmersal AZ201CC-T-1P2P Sicherheitsschalter mit Betätiger, sku: 103015814
Regular price
€534,63
Regular price
Sale price
€534,63
Unit price
/
per
Taxes included.
📦 Ready for dispatch: 30.11.2025
Couldn't load pickup availability
SKU: SKU:103015814
- Kunststoffgehäuse
- Bedarfsgerechter Manipulationsschutz durch RFID-Technologie
- max. Länge der Sensorkette 200 m
- selbstüberwachte Reihenschaltung
- 3 LEDs zur Anzeige der Betriebszustände
- Sensor-Technik erlaubt Versatz von Betätiger und Zuhaltung von vertikal ± 5 mm und horizontal ± 3 mm
- für Dreh- und Schiebetüren geeignet
- Intelligente Diagnose
- Product type description: AZ201CC-T-1P2P
- Article number (order number): 103015814
- EAN (European Article Number): 4030661504285
- eCl@ss number, version 12.0: 27-27-26-02
- eCl@ss number, version 11.0: 27-27-26-02
- eCl@ss number, version 9.0: 27-27-26-02
- ETIM number, version 7.0: EC002592
- ETIM number, version 6.0: EC002592
- Certificates: TÜV, cULus, FCC, IC, UKCA, ANATEL
- Standards: EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-3, EN IEC 61508
- Coding: Universal coding
- Coding level according to EN ISO 14119: Low
- Working principle: RFID, 125 kHz
- Transmitter output RFID, maximum: -6 dB/m
- Housing material: Glass-fibre, reinforced thermoplastic
- Duration of risk, maximum: 200 ms
- Reaction time, switching off safety outputs via actuator, maximum: 100 ms
- Reaction time, switching off safety outputs via safety inputs, maximum: 0.5 ms
- Gross weight: 392 g
- Short circuit detection: Yes
- Cross-circuit detection: Yes
- Series-wiring: Yes
- Safety functions: Yes
- Integral system diagnostics, status: Yes
- Number of safety contacts: 2
- Safety classification
- Standards: EN ISO 13849-1, EN IEC 61508
- Performance Level, up to: e
- Category: 4
- PFH value: 1.90 x 10⁻⁹ /h
- PFD value: 1.60 x 10⁻⁴
- Safety Integrity Level (SIL), suitable for applications in: 3
- Mission time: 20 Year(s)
- Mechanical life, minimum: 1,000,000 Operations
- Latching force: 30 N
- Actuating speed, maximum: 0.2 m/s
- Type of the fixing screws: 2x M6
- Tightening torque of the fastening screws for the housing cover, minimum: 0.7 Nm
- Tightening torque of the fastening screws for the housing cover, maximum: 1 Nm
- Note: Torx T10
- Assured switching distance "ON" Sao: 4 mm
- Assured switching distance "OFF" Sar: 30 mm
- Hysteresis (Switching distance), maximum: 1.5 mm
- Repeat accuracy R: 0.5 mm
- Length of sensor chain, maximum: 200 m
- Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current
- Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
- Termination: Spring pulley connection
- Cable section, minimum: 0.25 mm²
- Cable section, maximum: 1.5 mm²
- Note: All indications including the conductor ferrules.
- Wire cross-section, minimum: 23 AWG
- Wire cross-section, maximum: 15 AWG
- Wire cross-section: 23 ... 15 AWG
- Allowed type of cable: solid single-wire, solid multi-wire, flexible
- Length of sensor: 50 mm
- Width of sensor: 40 mm
- Height of sensor: 220 mm
- Degree of protection: IP66, IP67
- Ambient temperature: -25 ... +70 °C
- Storage and transport temperature: -25 ... +85 °C
- Relative humidity, maximum: 93 %
- Note (Relative humidity): non-condensing, non-icing
- Resistance to vibrations: 10 … 150 Hz, amplitude 0.35 mm
- Restistance to shock: 30 g / 11 ms
- Protection class: III
- Permissible installation altitude above sea level, maximum: 2,000 m
- Rated insulation voltage Ui: 32 VDC
- Rated impulse withstand voltage Uimp: 0.8 kV
- Overvoltage category: III
- Degree of pollution: 3
- Operating voltage: 24 VDC -15 % / +10 %
- No-load supply current I0, typical: 50 mA
- Rated operating voltage: 24 VDC
- Operating current: 700 mA
- Required rated short-circuit current: 100 A
- External wire and device fuse rating: 4A gG
- Time to readiness, maximum: 4,000 ms
- Switching frequency, maximum: 1 Hz
- Designation, Safety inputs: X1 and X2
- Switching thresholds: −3 V … 5 V (Low), 15 V … 30 V (High)
- Current consumption at 24 V: 5 mA
- Test pulse duration, maximum: 1 ms
- Test pulse interval, minimum: 100 ms
- Classification ZVEI CB24I, Sink: C1
- Classification ZVEI CB24I, Source: C1, C2, C3
- Designation, Safety outputs: Y1 and Y2
- Rated operating current (safety outputs): 250 mA
- Design of control elements: short-circuit proof, p-type
- Voltage drop Ud, maximum: 4 V
- Leakage current Ir, maximum: 0.5 mA
- Voltage, Utilisation category DC-13: 24 VDC
- Current, Utilisation category DC-13: 0.25 A
- Test pulse interval, typical: 1000 ms
- Test pulse duration, maximum: 0.5 ms
- Classification ZVEI CB24I, Source: C2
- Classification ZVEI CB24I, Sink: C1, C2
- Designation, Diagnostic outputs: OUT
- Operating current: 50 mA
- Design of control elements: short-circuit proof, p-type
- Voltage drop Ud, maximum: 4 V
- Voltage, Utilisation category DC-13: 24 VDC
- Current, Utilisation category DC-13: 0.05 A
- Note (LED switching conditions display): Operating condition: LED green, Error / functional defect: LED red, Supply voltage UB: LED green
- Scope of delivery: Actuator must be ordered separately.
- Recommendation (actuator): AZ/AZM201-B1, AZ/AZM201-B30