1
/
of
1
Schmersal
Schmersal AZM40Z-I1-ST-1P2P Sicherheitszuhaltungen, sku: 103034188
Schmersal AZM40Z-I1-ST-1P2P Sicherheitszuhaltungen, sku: 103034188
Regular price
€616,02
Regular price
Sale price
€616,02
Unit price
/
per
Taxes included.
📦 Ready for dispatch: 19.12.2025
Couldn't load pickup availability
SKU: SKU:103034188
- Kleine, flache Bauform
- 119,5 mm x 40 mm x 20 mm
- hohe Zuhaltekraft 2000 N
- Rastkraft 40 N
- Bedarfsgerechter Manipulationsschutz durch RFID-Technologie
- Individuell codierte Varianten mit Codierstufe hoch gemäß ISO 14119
- Nur eine Ausführung für Dreh- und Schiebetüren
- Betätiger kann Zuhaltung stufenlos innerhalb eines 180° Winkels anfahren.
- Symmetrischer Anbau, beidseitig anschraubbar
- Product type description: AZM40Z-I1-ST-1P2P
- Article number (order number): 103034188
- EAN (European Article Number): 4030661535135
- eCl@ss number, version 12.0: 27-27-26-03
- eCl@ss number, version 11.0: 27-27-26-03
- eCl@ss number, version 9.0: 27-27-26-03
- ETIM number, version 7.0: EC002593
- ETIM number, version 6.0: EC002593
- Certificates: TÜV, cULus, FCC, IC
- Standards: EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-3, EN IEC 61508
- Coding: Individual coding
- Coding level according to EN ISO 14119: High
- Working principle: RFID
- Frequency band RFID: 125 kHz
- Transmitter output RFID, maximum: -6 dB/m
- Enclosure material: Light alloy die cast and plastic (glass-fibre reinforced thermoplastic, self-extinguishing)
- Gross weight: 270 g
- Reaction time, maximum: 100 ms
- Duration of risk, maximum: 200 ms
- Reaction time, switching off safety outputs via safety inputs, maximum: 1.5 ms
- Solenoid interlock monitored: Yes
- Latching: Yes
- Manual release: Yes
- Short circuit detection: Yes
- Cross-circuit detection: Yes
- Series-wiring: Yes
- Safety functions: Yes
- Integral system diagnostics, status: Yes
- Number of safety contacts: 2
- Safety classification: 2
- Standards: EN ISO 13849-1, EN IEC 61508
- Performance Level, up to: e
- Category: 4
- PFH value: 1.10 x 10⁻⁹ /h
- PFD value: 8.90 x 10⁻⁵
- Safety Integrity Level (SIL), suitable for applications in: 3
- Mission time: 20 Year(s)
- Performance Level, up to: d
- Category: 2
- PFH value: 3.00 x 10⁻⁹ /h
- PFD value: 2.40 x 10⁻⁴
- Safety Integrity Level (SIL), suitable for applications in: 2
- Mission time: 20 Year(s)
- Interlocking principle: bistable
- Mechanical life, locking cycles: 1,000,000 Operations
- Mechanical life, actuator cycles: 200,000 Operations
- Holding force FZh in accordance with EN ISO 14119: 2,000 N
- Holding force Fmax, maximum: 2,600 N
- Latching force: 40 N
- Note (Latch force): +/- 25%
- Actuating speed, maximum: 0.5 m/s
- Mounting: mounting holes countersink
- Type of the fixing screws: 2x M5
- Tightening torque of the fixing screws, minimum: 4 Nm
- Assured switching distance "ON" Sao: 1 mm
- Assured switching distance "OFF" Sar: 8 mm
- Termination: Connector M12, 8-pole, A-coded
- Length of sensor chain, maximum: 30 m
- Note (length of the sensor chain): Cable length and cross-section change the voltage drop dependiing on the output current
- Note (series-wiring): Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
- Length of sensor: 119.5 mm
- Width of sensor: 40 mm
- Height of sensor: 20 mm
- Degree of protection: IP67, IP66
- Ambient temperature: +0 ... +55 °C
- Storage and transport temperature, minimum: -40 °C
- Storage and transport temperature, maximum: +85 °C
- Relative humidity, maximum: 93 %
- Note (Relative humidity): non-condensing, non-icing
- Resistance to vibrations: 10 … 55 Hz, amplitude 1 mm
- Restistance to shock: 30 g / 11 ms
- Protection class: III
- Permissible installation altitude above sea level, maximum: 2,000 m
- Rated insulation voltage Ui: 32 VDC
- Rated impulse withstand voltage Uimp: 0.8 kV
- Overvoltage category: III
- Degree of pollution: 3
- Operating voltage: 24 VDC -15 % / +10 % (stabilised PELV power supply)
- No-load supply current I0, maximum: 100 mA
- Rated operating voltage: 24 VDC
- Operating current: 1,200 mA
- Required rated short-circuit current: 100 A
- External wire and device fuse rating: 2 A gG
- Time to readiness, maximum: 4,000 ms
- Switching frequency, maximum: 0.25 Hz
- Current consumption magnet at switching moment, peak: 600 mA / 100ms
- Designation, Magnet control: IN
- Switching thresholds: -3 V … 5 V (Low), 15 V … 30 V (High)
- Magnet switch-on time: 100 %
- Test pulse duration, maximum: 5 ms
- Test pulse interval, minimum: 40 ms
- Classification ZVEI CB24I, Sink: C0
- Classification ZVEI CB24I, Source: C1, C2, C3
- Current consumption at 24V, minimum: 10 mA
- Current consumption at 24V, maximum: 15 mA
- Designation, Safety inputs: X1 and X2
- Switching thresholds: −3 V … 5 V (Low), 15 V … 30 V (High)
- Current consumption at 24 V: 5 mA
- Test pulse duration, maximum: 1 ms
- Test pulse interval, minimum: 100 ms
- Classification ZVEI CB24I, Sink: C1
- Classification ZVEI CB24I, Source: C1, C2, C3
- Designation, Safety outputs: Y1 and Y2
- Rated operating current (safety outputs): 250 mA
- Design of control elements: short-circuit proof, p-type
- Voltage drop Ud, maximum: 2 V
- Leakage current Ir, maximum: 0.5 mA
- Voltage, Utilisation category DC-12: 24 VDC
- Current, Utilisation category DC-12: 0.25 A
- Voltage, Utilisation category DC-13: 24 VDC
- Current, Utilisation category DC-13: 0.25 A
- Test pulse interval, typical: 1000 ms
- Test pulse duration, maximum: 0.5 ms
- Classification ZVEI CB24I, Source: C2
- Classification ZVEI CB24I, Sink: C1, C2
- Designation, Diagnostic outputs: OUT
- Design of control elements: short-circuit proof, p-type
- Voltage drop Ud, maximum: 2 V
- Voltage, Utilisation category DC-12: 24 VDC
- Current, Utilisation category DC-12: 0.05 A
- Voltage, Utilisation category DC-13: 24 VDC
- Current, Utilisation category DC-13: 0.05 A
- Note (LED switching conditions display): Operating condition: LED green, Error / functional defect: LED red, Supply voltage UB: LED green
- PIN 1: A1 Supply voltage UB
- PIN 2: X1 Safety input 1
- PIN 3: A2 GND
- PIN 4: Y1 Safety output 1
- PIN 5: OUT Diagnostic output
- PIN 6: X2 Safety input 2
- PIN 7: Y2 Safety output 2
- PIN 8: IN Solenoid control
- Recommendation (actuator): AZM40-B1