1
/
of
1
Schmersal
Schmersal SRB-E-302FWS-TS-OEM19 Stillstandswächter und Zeitrelais,sku: 103041191
Schmersal SRB-E-302FWS-TS-OEM19 Stillstandswächter und Zeitrelais,sku: 103041191
Regular price
€477,27
Regular price
Sale price
€477,27
Unit price
/
per
Taxes included.
📦 Ready for dispatch: 30.11.2025
Couldn't load pickup availability
SKU: SKU:103041191
- 2 Sicherheitskontakte, 1 Sicherheitsausgang
- Steckbare Schraubklemmen mit Codierung
- 1 Meldeausgang Bausteinstatus
- 1 Meldeausgang Fehlermeldung statisch
- Stillstandserfassung mit 1 oder 2 Impulsgebern
- zusätzliches Stillstandssignal als zweiten Eingangskanal
- 2-kanalige Zeitüberwachung
- Product type description: SRB-E-302FWS-TS-OEM19
- Article number (order number): 103041191
- EAN (European Article Number): 4030661560236
- eCl@ss number, version 12.0: 27-37-18-19
- eCl@ss number, version 11.0: 27-37-18-19
- eCl@ss number, version 9.0: 27-37-18-19
- ETIM number, version 7.0: EC001449
- ETIM number, version 6.0: EC001449
- Certificates: cULus, CCC
- Standards: EN IEC 62061, EN ISO 13849-1, EN IEC 60947-5-1, EN IEC 60947-5-3, EN IEC 60947-5-5, EN IEC 61508, EN IEC 60204-1, EN IEC 60947-1
- Climatic stress: EN 60068-2-78
- Housing material: Glass-fibre reinforced thermoplastic, ventilated
- Gross weight: 170 g
- Electronic Fuse: Yes
- Wire breakage detection : Yes
- Cross-circuit detection: Yes
- Start input: Yes
- Feedback circuit : Yes
- Automatic reset function: Yes
- Reset edge detection: Yes
- Earth connection detection: Yes
- Integral system diagnostics, status: Yes
- Number of inputs for NC: 2
- Number of inputs for NO: 1
- Number of LEDs: 6
- Number of safety contacts: 2
- Number of fail-safe digital outputs: 1
- Number of signalling outputs: 2
- Safety classification
- Standards: EN ISO 13849-1, EN IEC 62061, EN IEC 61508
- Stop-Category: 0
- Safety classification - Relay outputs
- Performance Level, up to: e
- Category: 4
- Diagnostic Coverage (DC) Level: > 94 %
- PFH value: 1.25 x 10⁻⁸ /h
- PFD value: 5.30 x 10⁻⁵
- Safety Integrity Level (SIL), suitable for applications in: 3
- Mission time: 20 Year(s)
- Common Cause Failure (CCF), minimum: 65
- Safety classification - Fail-safe digital outputs
- Performance Level, up to: e
- Category: 4
- PFH value: 2.66 x 10⁻⁹ /h
- PFD value: 2.42 x 10⁻⁵
- Safety Integrity Level (SIL), suitable for applications in: 3
- Mission time: 20 Year(s)
- Mechanical life, minimum: 10,000,000 Operations
- Mounting: Snaps onto standard DIN rail to EN 60715
- Terminal designations: IEC 60947-1
- Termination: rigid or flexible, Screw connection, plug-in
- Cable section, minimum: 0.25 mm²
- Cable section, maximum: 2.5 mm²
- Tightening torque of Clips: 0.5 Nm
- Width: 22.5 mm
- Height: 98 mm
- Depth: 115 mm
- Degree of protection of the enclosure: IP40
- Degree of protection of the mounting space: IP54
- Degree of protection of clips or terminals: IP20
- Ambient temperature: -25 ... +60 °C
- Storage and transport temperature: -40 ... +85 °C
- Resistance to vibrations: 10 ... 55 Hz, Amplitude 0.35 mm
- Restistance to shock: 30 g / 11 ms
- Rated insulation voltage Ui: 250 V / 50 V
- Rated impulse withstand voltage Uimp, relay output: 4 kV
- Rated impulse withstand voltage Uimp, semiconductor output: 0.8 kV
- Overvoltage category: III
- Degree of pollution: 2
- Operating voltage: 24 VDC -20 % / +20 %
- Ripple voltage: 10 %
- Rated operating voltage: 24 VDC
- Operating current: 125 mA
- Rated AC voltage for controls at DC minimum: 19.2 VDC
- Rated control voltage at DC, maximum: 28.8 VDC
- Electrical power consumption: 3 W
- Contact resistance, maximum: 0.1 Ω
- Note (Contact resistance): in new state
- Drop-out delay in case of power failure, typically: 10 ms
- Drop-out delay in case of emergency, typically: 10 ms
- Pull-in delay at automatic start, maximum, typically: 150 ms
- ON delay at automatic start: Adjustable
- Pull-in delay at RESET, typically: 150 ms
- Switching frequency, maximum: 0.3 Hz
- Material of the contacts, electrical: Ag-Ni, self-cleaning, positive drive
- Voltage drop Ud, maximum: 0.5 V
- Leakage current Ir, maximum: 1 mA
- Voltage, Utilisation category DC-13: 24 VDC
- Current, Utilisation category DC-13: 2 A
- Voltage, Utilisation category AC-15: 230 VAC
- Current, Utilisation category AC-15: 4 A
- Voltage, Utilisation category DC-13: 24 VDC
- Current, Utilisation category DC-13: 4 A
- Switching capacity, minimum: 10 VDC
- Switching capacity, minimum: 10 mA
- Switching capacity, maximum: 250 VAC
- Switching capacity, maximum: 6 A
- Conduction resistance, maximum: 40 Ω
- Voltage, Utilisation category DC-12: 24 VDC
- Current, Utilisation category DC-12: 0.1 A
- Switching capacity, maximum: 24 VDC
- Switching capacity, maximum: 1 A
- EMC rating: EMC-Directive
- Indicated operating states: Internal operating voltage Ui, Baustein-Status, Fault codes
- Note (applications): safe standstill monitoring, Fail-safe delay timer