SKU: SKU:FXFF007

weFlux² flow sensors simultaneously measure flow velocity and the temperature of aqueous liquids regardless of position and flow direction. The advantage: The number of measuring points and the diversity of sensor variants are cut in half, ensuring the greatest possible flexibility when installing in closed piping systems. Either 2 switching outputs or 1 switching output and 1 analog output are available depending on application requirements. The outputs can be configured as desired via IO-Link in order to flexibly adapt the sensors to the respective application.

  • A single sensor for flow and temperature
  • FDA compliant
  • Ready for Industry 4.0 with IO-Link 1.1
  • Measurement independent of flow direction and instillation position
Sensor-specific data
Measuring Range 10 ... 400 cm/s
Temperature of the medium, flow measurement 0 ... 125 °C**
Temperature of the medium, temperature measurement -25 ... 150 °C
Setting Range 10 ... 400 cm/s
Medium Water
Measuring error (total) ≤ 2 %
MTTFd (EN ISO 13849-1) 1,210.41 a
Response time in case of temperature jump 10 s
Environmental conditions
Ambient temperature -25 ... 80 °C
Storage temperature -25 ... 80 °C
Pressure Resistance 100 bar
EMC DIN EN 61326-1
Shock resistance per DIN IEC 68-2-27 30 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6 5 g (10...2000 Hz)
Electrical Data
Supply Voltage 12 ... 32 V DC
Current Consumption (Ub = 24 V) < 40 mA
Number of Switching Outputs 2
Number of analog outputs 1
Analog Output 4...20 mA
Signal source Flow
Response Time 1 ... 5 s
Switching Output/Switching Current ± 100 mA
Switching Output Voltage Drop < 2 V
Load Current Voltage Output ≤ 20 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Protection Class III
Interface IO-Link V1.1
Mechanical Data
Setting Method IO-Link
Housing Material Stainless steel, V4A (1.4404/316L)
Material in contact with media Stainless steel, V4A (1.4404/316L)
Degree of Protection IP69K *IP68 *
Connection M12 × 1; 4-pin
Process Connection G 1/4"
Process Connection Length (PCL) 45 mm
Probe Length (PL) 9.5 mm
Weight 256 g
Output
Analog output flow yes
IO-Link yes
PNP NO yes
Adjustable parameters
Output Analog OutputPush-pullNPNPNP
Analog output 0...10 V4...20 mA
Signal source FlowTemperature
Circuit NCNC/NONO
Other parameters 2 switching pointsSelectable measurement range
All other parameters can be found in the product documentation.
Standards and certificates
* Certified by wenglor** The sensors were calibrated and specified for the medium water. Technically, the sensors are suitable for a medium temperature of up to -25 °C. To achieve a temperature below 0 °C, a different medium must be added to the water. This leads to a different measurement result, which is why an application below 0 °C must be tested individually for the mixture used.