weFlux² flow sensors simultaneously measure flow velocity and the temperature of aqueous liquids regardless of position and flow direction. The advantage: The number of measuring points and the diversity of sensor variants are cut in half, ensuring the greatest possible flexibility when installing in closed piping systems. Either 2 switching outputs or 1 switching output and 1 analog output are available depending on application requirements. The outputs can be configured as desired via IO-Link in order to flexibly adapt the sensors to the respective application.
A single sensor for flow and temperature
FDA compliant
Ready for Industry 4.0 with IO-Link 1.1
Measurement independent of flow direction and instillation position
Sensor-specific data
Measuring Range
10 ... 400 cm/s
Temperature of the medium, flow measurement
0 ... 125 °C**
Temperature of the medium, temperature measurement
-25 ... 150 °C
Setting Range
10 ... 400 cm/s
Medium
Water
Measuring error (total)
≤ 2 %
MTTFd (EN ISO 13849-1)
1,210.41 a
Response time in case of temperature jump
10 s
Environmental conditions
Ambient temperature
-25 ... 80 °C
Storage temperature
-25 ... 80 °C
Pressure Resistance
100 bar
EMC
DIN EN 61326-1
Shock resistance per DIN IEC 68-2-27
30 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6
5 g (10...2000 Hz)
Electrical Data
Supply Voltage
12 ... 32 V DC
Current Consumption (Ub = 24 V)
< 40 mA
Number of Switching Outputs
2
Number of analog outputs
1
Analog Output
4...20 mA
Signal source
Flow
Response Time
1 ... 5 s
Switching Output/Switching Current
± 100 mA
Switching Output Voltage Drop
< 2 V
Load Current Voltage Output
≤ 20 mA
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Protection Class
III
Interface
IO-Link V1.1
Mechanical Data
Setting Method
IO-Link
Housing Material
Stainless steel, V4A (1.4404/316L)
Material in contact with media
Stainless steel, V4A (1.4404/316L)
Degree of Protection
IP69K *IP68 *
Connection
M12 × 1; 4-pin
Process Connection
G 1/2" CIP-capable
Process Connection Length (PCL)
60 mm
Probe Length (PL)
16.4 mm
Weight
304 g
Output
Analog output flow
yes
IO-Link
yes
PNP NO
yes
Adjustable parameters
Output
Analog OutputPush-pullNPNPNP
Analog output
0...10 V4...20 mA
Signal source
FlowTemperature
Circuit
NCNC/NONO
Other parameters
2 switching pointsSelectable measurement range
All other parameters can be found in the product documentation.
Standards and certificates
* Certified by wenglor** The sensors were calibrated and specified for the medium water. Technically, the sensors are suitable for a medium temperature of up to -25 °C. To achieve a temperature below 0 °C, a different medium must be added to the water. This leads to a different measurement result, which is why an application below 0 °C must be tested individually for the mixture used.
Connection Diagram
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")Wrench Size