Wenglor

Wenglor FXFF102, Flow Sensor

Wenglor FXFF102, Flow Sensor

Regular price €528,36
Regular price Sale price €528,36
Sale Sold out
Taxes included.

📦 Ready for dispatch: 16.12.2025

SKU: SKU:FXFF102

weFlux² Flow Sensors with two analog outputs simultaneously measure flow velocity and the temperature of aqueous liquids regardless of position and direction of flow. Advantage: The number of measuring points and the diversity of sensor variants are cut in half, and greatest possible flexibility is assured for installation in closed piping systems. The analysis module is integrated into the compact housing.

  • 2 analog outputs: 4 ... 20 mA
  • FDA compliant
  • A single sensor for flow and temperature
  • Measurement independent of flow direction and instillation position
Sensor-specific data
Measuring Range 10 ... 400 cm/s
Temperature of the medium, flow measurement 0 ... 125 °C**
Temperature of the medium, temperature measurement -25 ... 150 °C
Setting Range 10 ... 400 cm/s
Medium Water
Measuring error (total) ≤ 2 %
MTTFd (EN ISO 13849-1) 1,210.41 a
Response time in case of temperature jump 10 s
Environmental conditions
Ambient temperature -25 ... 80 °C
Storage temperature -25 ... 80 °C
Pressure Resistance 100 bar
EMC DIN EN 61326-1
Shock resistance per DIN IEC 68-2-27 30 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6 5 g (10...2000 Hz)
Electrical Data
Supply Voltage 12 ... 32 V DC
Current Consumption (Ub = 24 V) < 40 mA
Number of analog outputs 2
Analog Output 4...20 mA
Signal source FlowTemperature
Response Time 1 ... 5 s
Short Circuit Protection yes
Reverse Polarity Protection yes
Protection Class III
Mechanical Data
Housing Material Stainless steel, V4A (1.4404/316L)
Material in contact with media Stainless steel, V4A (1.4404/316L)
Degree of Protection IP69K *IP68 *
Connection M12 × 1; 4-pin
Process Connection Cutting/locking ring
Process Connection Length (PCL) 109 mm
Probe Length (PL) 100 mm
Weight 228 g
Output
Analog output flow yes
Analog output temperature yes
Standards and certificates
* Certified by wenglor** The sensors were calibrated and specified for the medium water. Technically, the sensors are suitable for a medium temperature of up to -25 °C. To achieve a temperature below 0 °C, a different medium must be added to the water. This leads to a different measurement result, which is why an application below 0 °C must be tested individually for the mixture used.
Connection Diagram
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")Wrench Size
Complementary Products
  • IO-Link converter
  • ZH6C00x Adapter to G1/4"
  • Software
View full details