weFlux² Flow Sensors with two analog outputs simultaneously measure flow velocity and the temperature of aqueous liquids regardless of position and direction of flow. Advantage: The number of measuring points and the diversity of sensor variants are cut in half, and greatest possible flexibility is assured for installation in closed piping systems. The analysis module is integrated into the compact housing.
2 analog outputs: 4 ... 20 mA
FDA compliant
A single sensor for flow and temperature
Measurement independent of flow direction and instillation position
Sensor-specific data
Measuring Range
10 ... 400 cm/s
Temperature of the medium, flow measurement
0 ... 125 °C**
Temperature of the medium, temperature measurement
-25 ... 150 °C
Setting Range
10 ... 400 cm/s
Medium
Water
Measuring error (total)
≤ 2 %
MTTFd (EN ISO 13849-1)
1,210.41 a
Response time in case of temperature jump
10 s
Environmental conditions
Ambient temperature
-25 ... 80 °C
Storage temperature
-25 ... 80 °C
Pressure Resistance
100 bar
EMC
DIN EN 61326-1
Shock resistance per DIN IEC 68-2-27
30 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6
5 g (10...2000 Hz)
Electrical Data
Supply Voltage
12 ... 32 V DC
Current Consumption (Ub = 24 V)
< 40 mA
Number of analog outputs
2
Analog Output
4...20 mA
Signal source
Flow
Response Time
1 ... 5 s
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Protection Class
III
Mechanical Data
Housing Material
Stainless steel, V4A (1.4404/316L)
Material in contact with media
Stainless steel, V4A (1.4404/316L)
Degree of Protection
IP69K *IP68 *
Connection
M12 × 1; 4-pin
Process Connection
G 1/2"
Process Connection Length (PCL)
72.5 mm
Probe Length (PL)
32 mm
Weight
325 g
Output
Analog output flow
yes
Analog output temperature
yes
Adjustable parameters
Signal source
FlowTemperature
All other parameters can be found in the product documentation.
Standards and certificates
* Certified by wenglor** The sensors were calibrated and specified for the medium water. Technically, the sensors are suitable for a medium temperature of up to -25 °C. To achieve a temperature below 0 °C, a different medium must be added to the water. This leads to a different measurement result, which is why an application below 0 °C must be tested individually for the mixture used.
Connection Diagram
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")Wrench Size