LevelTech fill-level sensors work in accordance with the innovative frequency sweep principle. With the help of this functional principle, the sensors detect any desired medium on the basis of the measured resonant frequency. With their two adjustable switching outputs, the sensors are capable of differentiating between foam and liquid or two different media. Sensor parameters, as well as filter and output functions, can be individually configured via IO-Link. The stainless steel housing is FDA compliant and can be installed in the tightest of spaces thanks to its compact design.
Fill-level measurement in all media: liquid, pasty, sticky or solid
Process optimization with IO-Link 1.1
Quick sensor replacement with data storage
Two adjustable switching outputs
With status LEDs
Sensor-specific data
Measuring principle
Frequency sweep
Measuring Range > DK***
1.5
Medium
Liquids, granulate, powder
Response Time
0.04 s
Environmental conditions
Media temperature TM (TU < 50 °C)
-40 ... 115 °C**
Media temperature TM brief(TU < 50 °C, t < 1 h)
-40 ... 130 °C
Ambient temperature
-40 ... 85 °C
Storage temperature
-40 ... 85 °C
Pressure Resistance
100 bar
EMC
DIN EN 61326 *
Vibration resistance per DIN IEC 60068-2-6
1,6 mm p-p (2...25 Hz), 4 g (25...100 Hz)
Electrical Data
Supply Voltage
8 ... 36 V DC
Current Consumption (Ub = 24 V)
< 35 mA
Number of Switching Outputs
2
Power-up Time
< 3 s
Switching Output/Switching Current
100 mA
Switching Output Voltage Drop
< 0.7 V
Signal source
Change of medium
Leakage Current
< 100 µA
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Interface
IO-Link V1.1
Mechanical Data
Setting Method
Teach-in/IO-Link
Housing Material
Stainless steel, V4A (1.4404/316L)Plastic, PC
Material in contact with media
Plastic, PEEK
Degree of Protection
IP67IP69K
Connection
M12 × 1; 4-pin
Connector Plug Material
Polycarbonate
Process Connection
1/2” NPT
Weight
71 g
Safety-relevant Data
MTTFd (EN ISO 13849-1)
686 a
Function
Attenuation (adjustable)
0 ... 10 s
Selective fill-level measurement
yes
Output
IO-Link
yes
Push-Pull
yes
Adjustable parameters
Output
Push-pullNPNPNP
Circuit
NCNC/NONO
Other parameters
2 switching points
All other parameters can be found in the product documentation.
Standards and certificates
* mounted in closed metal tank** TM= temperature of medium; TU= ambient temperature*** The relative dielectric constant of the medium to be detected must be greater than 1.5. (DC = dielectric constant)