These sensors can measure distances and display analog output. Their high resolution and wide variety of measuring ranges allow them to be used in innumerable applications. The output signal is practically independent of the object's color.
Error message
Red light
Analog output
Optical Data
Working Range
35 ... 85 mm
Measuring Distance
60 mm
Measuring Range
50 mm
Resolution
500 µm
Linearity
< 2 %
Light Source
Red Light
Wavelength
660 nm
Service Life (T = +25 °C)
100,000 h
Max. Ambient Light
10,000 Lux
Light Spot Diameter
2 mm
Electrical Data
Supply Voltage
18 ... 30 V DC
Current Consumption (Ub = 24 V)
< 40 mA
Cut-Off Frequency
100 Hz
Response Time
5 ms
Temperature Drift
35 µm/K
Temperature Range
-10 ... 60 °C
PNP Error Output/Switching Current
200 mA
Analog Output
0...10 V
Output Current Analog Output
500 µA
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Protection Class
III
Mechanical Data
Housing Material
Stainless steel, V2A (1.4305 / 303)
Full Encapsulation
yes
Degree of Protection
IP67
Connection
Cable; 6-wire
Cable length (L)
6 m
Cable Jacket Material
PVC
Wire cross-section
0.14 mm²
Weight
290 g
Output
Analog Output
yes
Standards and certificates
Connection Diagram
Error of Measurement
Typical characteristic curve based on white, 90 % remissionS = Measuring DistancedS = Deviationblack 6 % remissiongrey 18 % remission
Ctrl. Panel
12 = Analog Output Indicator79 = Run/Error Indicator
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")1 = Receiver Diode2 = Transmitter DiodeWrench Size