These sensors can measure distances and display analog output. Their high resolution and wide variety of measuring ranges allow them to be used in innumerable applications. The output signal is practically independent of the object's color.
Analog output (0...10 V DC)
Error output
Red light
Large measuring range
Optical Data
Working Range
55 ... 155 mm
Measuring Distance
105 mm
Measuring Range
100 mm
Resolution
500 µm
Linearity
1 %
Light Source
Red Light
Wavelength
660 nm
Service Life (T = +25 °C)
100,000 h
Max. Ambient Light
10,000 Lux
Light Spot Diameter
3 mm
Electrical Data
Supply Voltage
18 ... 30 V DC
Current Consumption (Ub = 24 V)
< 40 mA
Cut-Off Frequency
100 Hz
Response Time
5 ms
Temperature Drift
50 µm/K
Temperature Range
-10 ... 60 °C
PNP Error Output/Switching Current
200 mA
Analog Output
0...10 V
Output Current Analog Output
500 µA
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Protection Class
III
Mechanical Data
Housing Material
Plastic, PBT
Optic Cover
Glass
Full Encapsulation
yes
Degree of Protection
IP67
Connection
Cable; 6-wire
Cable length (L)
6 m
Cable Jacket Material
PVC
Wire cross-section
0.25 mm²
Weight
388 g
Safety-relevant Data
MTTFd (EN ISO 13849-1)
2,142.98 a
Output
Error Output
yes
Analog Output
yes
Standards and certificates
Actual product not similar
Connection Diagram
Error of Measurement
Typical characteristic curve based on white, 90 % remissionS = Measuring DistancedS = Deviationblack 6 % remissiongrey 18 % remission
Ctrl. Panel
12 = Analog Output Indicator03 = Error Indicator
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")1 = Transmitter Diode2 = Receiver DiodeScrew M4 = 1 Nm