The Inductive Sensors have not only been equipped with ASIC, but rather with an IO-Link interface as well for ideal integration into networks. As a result, a total of three switching distances and two switching frequencies can be selected, and PNP/NPN as well as NO/NC/antivalent options can be set as desired. This reduces the number of variants while simultaneously expanding the scope of functions.
Easy sensor configuration using the IO-Link interface
Minimal mounting clearance thanks to wenglor weproTec
Innovative ASIC circuit technology
Integrated error display and error output
Adjustable switching distance
Inductive Data
Switching Distance
6 mm
Standard Target
18 × 18 mm
Correction Factors Stainless Steel V2A/CuZn/Al
1,11/0,53/0,50
Mounting
semi-flush
Mounting A/B/C/D in mm
12/26/18/4
Mounting B1 in mm
0...13
Switching Hysteresis
< 10 %
Electrical Data
Supply Voltage
10 ... 30 V DC
Supply Voltage with IO-Link
18 ... 30 V DC
Current Consumption (Ub = 24 V)
< 12 mA
Switching Frequency
770 Hz
Temperature Drift
< 10 %
Temperature Range
-40 ... 80 °C
Switching Output Voltage Drop
< 1 V
Switching Output/Switching Current
150 mA
Residual Current Switching Output
< 100 µA
Short Circuit Protection
yes
Overload Protection
yes
Reverse Polarity Protection
yes
Interface
IO-Link V1.1
Protection Class
III
Mechanical Data
Housing Material
Brass, nickel-plated
Degree of Protection
IP67
Connection
M12 × 1; 4-pin
Weight
16 g
Safety-relevant Data
MTTFd (EN ISO 13849-1)
3,706.54 a
General Data
Packaging unit
1 Piece
Function
Error Indicator
yes
Programmable switching distance
4/5/6 mm
Programmable switching frequency
yes
Output
IO-Link
yes
Programmable error output
yes
PNP NO
yes
Adjustable parameters
Output
Error OutputPush-pullPNPNPN
Circuit
NCNC/NONO
Standards and certificates
Connection Diagram
Mounting
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")1 = Switching Status IndicatorSleeve M12×1 = 12 NmWrench Size