The Inductive Sensors have not only been equipped with ASIC, but rather with an IO-Link interface as well for ideal integration into networks. As a result, a total of three switching distances and two switching frequencies can be selected, and PNP/NPN as well as NO/NC/antivalent options can be set as desired. This reduces the number of variants while simultaneously expanding the scope of functions.
Minimal mounting clearance thanks to wenglor weproTec
Innovative ASIC circuit technology
Easy sensor configuration using the IO-Link interface
Integrated error display and error output
Adjustable switching distance
Inductive Data
Switching Distance
20 mm
Standard Target
60 × 60 mm
Correction Factors Stainless Steel V2A/CuZn/Al
0,83/0,32/0,31
Mounting
Flush
Mounting A/B/C/D in mm
0/40/60/0
Mounting B1 in mm
6...35
Switching Hysteresis
< 10 %
Electrical Data
Supply Voltage
10 ... 30 V DC
Supply Voltage with IO-Link
18 ... 30 V DC
Current Consumption (Ub = 24 V)
< 15 mA
Switching Frequency
700 Hz
Temperature Drift
< 10 %
Temperature Range
-40 ... 80 °C
Switching Output Voltage Drop
< 1 V
Switching Output/Switching Current
150 mA
Residual Current Switching Output
< 100 µA
Short Circuit Protection
yes
Overload Protection
yes
Reverse Polarity Protection
yes
Interface
IO-Link V1.1
Protection Class
III
Mechanical Data
Housing Material
Plastic, ABS
Sensing face
Plastic, PBT
Full Encapsulation
yes
Degree of Protection
IP67
Connection
M12 × 1; 4-pin
Weight
102 g
Safety-relevant Data
MTTFd (EN ISO 13849-1)
3,706.54 a
General Data
Packaging unit
1 Piece
Function
Error Indicator
yes
Programmable switching distance
12/15/20 mm
Programmable switching frequency
yes
Output
IO-Link
yes
Programmable error output
yes
PNP NO
yes
Adjustable parameters
Output
Error OutputPush-pullNPNPNP
Circuit
NCNC/NONO
Standards and certificates
Connection Diagram
Mounting
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")1 = Switching Status Indicator