Welding field resistant inductive sensors with correction factor 1 offer a unique combination of technical performance features: increased switching distances for reliable object detection, high switching frequencies for applications with high process speeds and an extended temperature range for use under various ambient conditions. A switching status LED for diagnosis functions reduces system downtime. In order to simplify integration, all housing designs are available in flush or non-flush mounting variants.
Extended temperature range
Greatest possible switching distances with correction factor 1
Very good magnetic and electromagnetic immunity
Very high switching frequency
Inductive Data
Switching Distance
15 mm
Correction Factors Stainless Steel V2A/CuZn/Al
1,06/1,06/1,07
Mounting
Flush
Mounting A/B/C/D in mm
0/15/45/0
Switching Hysteresis
< 15 %
Electrical Data
Supply Voltage
10 ... 30 V DC
Current Consumption (Ub = 24 V)
< 15 mA
Switching Frequency
2,000 Hz
Temperature Drift (-25 °C < Tu < 60 °C)
10 %
Temperature Drift (Tu 60 °C)
20 %
Temperature Range
-40 ... 80 °C
Switching Output Voltage Drop
< 2.5 V
Switching Output/Switching Current
200 mA
Resistant to Magnetic Fields
200 mT
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Overload Protection
yes
Protection Class
II
Protective Insulation, Rated Voltage
150 V
Mechanical Data
Housing Material
PTFEBrass, nickel-plated
Sensing face
Plastic, PBT
Welding Field Resistant
yes
Full Encapsulation
yes
Degree of Protection
IP67
Connection
M12 × 1; 4-pin
Weight
144 g
Safety-relevant Data
MTTFd (EN ISO 13849-1)
2,157.87 a
General Data
Packaging unit
1 Piece
Function
Error Indicator
yes
Output
PNP NC, PNP NO
yes
Adjustable parameters
Circuit
NCNC+NONO
Standards and certificates
Connection Diagram
Mounting
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")1 = Switching Status IndicatorSleeve M30×1,5 = 35 Nm