These sensors work with a high-resolution CMOS line and DSP technology and determine distance using angular measurement. As a result, material, color and brightness related measurement differences are virtually eliminated.

Integrated analogue output can be configured for voltage 0...10 V (10...0 V) or current 4...20 mA (20...4 mA).

  • Zoom function
  • Measured value independent of material, color and brightness
  • Emitted light disengageable
  • CMOS line array
  • Laser class 1
Optical Data
Working Range 50 ... 350 mm
Measuring Range 300 mm
Reproducibility maximum 1,200 µm
Reproducibility: 1 Sigma 400 µm
Linearity Deviation 1,000 µm
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 10,000 Lux
Light Spot Diameter see Table 1
Electrical Data
Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 80 mA
Measuring Rate 500 /s
Measuring Rate (Resolution-Mode) 250 /s
Response Time 2,000 µs
Response Time (Resolution Mode) < 4,000 µs
Temperature Drift < 75 µm/K
Temperature Range -25 ... 50 °C
Analog Output 0...10 V
Load Current Voltage Output < 1 mA
Current Output Load Resistance < 500 Ohm
Interface RS-232
Transmission rate 38,400 Bd
Protection Class III
FDA Accession Number 1120723-000
Mechanical Data
Setting Method Teach-In
Housing Material Plastic, ABSPlastic, PC
Optic Cover Plastic, PMMA
Degree of Protection IP67
Connection M12 × 1; 8-pin
Weight 45 g
Safety-relevant Data
MTTFd (EN ISO 13849-1) 713.97 a
Output
Error Output yes
Analog Output yes
RS-232 Interface yes
Adjustable parameters
Analog output 0...10 V4...20 mA
Other parameters Scale analog outputExposure timeFilterLaser lightResolution modeSpeed mode
All other parameters can be found in the product documentation.
Standards and certificates
Table 1
Working Distance 50 mm 350 mm
Spot Size 0,4 × 1 mm 1,4 × 3,1 mm
Connection Diagram
Output Graph
c = Measuring Rangea = Analog Voltage Output
Ctrl. Panel
07 = Selector Switch12 = Analog Output Indicator03 = Error Indicator24 = Plus Button25 = Minus Button63 = Analog Output Current Indicator
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")1 = Transmitter Diode2 = Receiver DiodeScrew M4 = 0.5 Nm
Complementary Products
  • Analog Evaluation Unit AW02
  • Fieldbus Gateway ZAGxxxN01, EPGG001
  • IO-Link converter
  • Interface Cable S232W3
  • Protective Housing ZSV-0x-01
  • Set Protective Housing ZSP-NN-02
  • Software
View full details