Wenglor

Wenglor OEEI152U0135, Light Curtain for Measuring Tasks

Wenglor OEEI152U0135, Light Curtain for Measuring Tasks

Regular price €690,20
Regular price Sale price €690,20
Sale Sold out
Taxes included.

📦 Ready for dispatch: 03.12.2025

SKU: SKU:OEEI152U0135

As these light curtains for measurement task are equipped with an integrated evaluation unit, external connection units are not needed. Objects are both recognized (via the digital output) and measured (via the analog output). The light curtains can be set up easily using the menu-controlled graphic display. Convenient parametrization and quick diagnosis is possible via the IO-Link interface. The adequate mounting angle BEF-SET-33 is included in the delivery.

  • Graphical display for easy operation
  • Integrated evaluation unit
  • Recognition of small parts
  • Object detection and measurement
Optical Data
Range 2,000 mm
Measurement Field Height (MFH) 150 mm
Beam Distance 2 mm
Light Source Infrared Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux
Opening Angle 10 °
Electrical Data
Sensor Type Receiver
Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 60 mA
Switching Frequency 60 Hz
Response Time 8 ms
On-/Off-Delay 0 ... 10 s
Temperature Drift < 10 %
Temperature Range -25 ... 60 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 2.5 V
Switching Output/Switching Current 100 mA
Residual Current Switching Output < 50 µA
Analog Output 0...10 V
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Interface IO-Link V1.0
Protection Class III
Mechanical Data
Setting Method Menu (OLED)
Housing Material Aluminum, powder-coatedPlastic, PAPlastic, PBT
Optic Cover Plastic, PC
Degree of Protection IP65
Connection M12 × 1; 5-pin
Weight 465 g
Safety-relevant Data
MTTFd (EN ISO 13849-1) 147.29 a
Output
PNP NC yes
IO-Link yes
External teach-in input yes
Adjustable parameters
Analog output 0...10 V4...20 mA
Output Analog OutputError OutputPush-pullPNP
Circuit NCNC/NONO
Other parameters Off-delayOn-delay
All other parameters can be found in the product documentation.
Standards and certificates
Display brightness may decrease with age. This does not result in any impairment of the sensor function.
Connection Diagram
Ctrl. Panel
20 = Enter key22 = Up key23 = Down key60 = display
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")
Complementary Products
  • IO-Link converter
  • Analog Evaluation Unit AW02
  • IO-Link Master
  • Software