1
/
of
0
Wenglor
Wenglor OPT1546, Logic Unit for Roller Conveyor Systems
Wenglor OPT1546, Logic Unit for Roller Conveyor Systems
Regular price
€633,08
Regular price
Sale price
€633,08
Unit price
/
per
Taxes included.
📦 Ready for dispatch: 03.12.2025
Couldn't load pickup availability
SKU: SKU:OPT1546
These devices have been specially designed for use in accumulation roller conveyors. Their compact design allows for installation between rollers below the transport level.
They're equipped with their own sensor optics, and object detection is handled by externally connected sensor technology. Settings are entered via wireless NFC, which is even possible in the de-energized state. Thanks to the innovative fast-clip mounting system and quick wiring, the devices are installed and ready for use in no time flat.
- Optimized performance
- Energy savings thanks to EcoMode
- Increased capacity thanks to intelligent functions
- Time-saving initial start-up with fast-clip mounting system and quick wiring
- Wireless settings via NFC
| Optical Data | |
|---|---|
| Service Life (T = +25 °C) | 100,000 h |
| Electrical Data | |
|---|---|
| Supply Voltage | 20.6 ... 30 V DC |
| Current Consumption Sensor (Ub = 24 V) | < 16 mA |
| EcoMode | yes |
| Switching Frequency | 100 Hz |
| Response Time | 5 ms |
| Temperature Range | -40 ... 60 °C |
| Number of Switching Outputs | 2 |
| Switching Output Voltage Drop | < 0.9 V |
| PNP Switching Output/Switching Current | 200 mA |
| Short Circuit Protection | yes |
| Reverse Polarity Protection | yes |
| Overload Protection | yes |
| Logic | yes |
| Single Discharge | yes |
| Block Forwarding | yes |
| Solenoid Valve | yes |
| Automatic Roller Shutdown | yes |
| Protection Class | III |
| Mechanical Data | |
|---|---|
| Setting Method | NFC |
| Housing Material | Plastic, ABS/GF |
| Degree of Protection | IP65 |
| Connection | M12 × 1; 4-pin |
| Cable length (L) | 1 m |
| Cable Jacket Material | PVC |
| Weight | 238 g |
| Pneumatic Solenoid Valve Unit | |
|---|---|
| Valve no. | K04 |
| Supply Voltage Valve | 19.2 ... 28.8 V |
| Current Consumption Valve | 86 mA |
| Valve temperature range | -15 ... 50 °C |
| Operating Pressure | 4 ... 7 bar |
| Nominal Width | 0.8 mm |
| Nominal flow rate 1 -> 2 | 20 NL/min |
| Nominal flow rate 2 -> 3 | 100 NL/min |
| Supply-Line Connector Pipe | 2× 8×1 |
| Working-Line Connector Pipe | 4×1 |
| Valve function | 3/2-Way |
| Switching function | NC |
| Output | |
|---|---|
| PNP NO/NC switchable | yes |
| NFC Receiver Category | yes |
| Standards and certificates |
|---|
| Connection Diagram |
|---|
| Ctrl. Panel |
|---|
| 2a = NFC interface3a = Switching Status Indicator/Error Indicator |
| Dimensioned Picture |
|---|
| Dimensions specified in mm (1 mm = 0.03937")Screw M4 = 0.5 Nm |
| Complementary Products |
|---|
|