1
/
of
0
Wenglor
Wenglor OPT339-P06, Logic Unit for Roller Conveyor Systems
Wenglor OPT339-P06, Logic Unit for Roller Conveyor Systems
Regular price
€423,64
Regular price
Sale price
€423,64
Unit price
/
per
Taxes included.
📦 Ready for dispatch: 03.12.2025
Couldn't load pickup availability
SKU: SKU:OPT339-P06
These sensors have been specially designed for use in accumulation roller conveyors. Their compact design allows for installation between two rollers below the conveyor level. They are thus protected against mechanical damage.
- Integrated logic
- Fully encapsulated
- Energy-saving trough automatic roll cutoff
| Electrical Data | |
|---|---|
| Supply Voltage | 18 ... 30 V DC |
| Current Consumption Sensor (Ub = 24 V) | < 10 mA |
| Off-Delay | 0 ... 2 s |
| Temperature Range | -25 ... 60 °C |
| Number of Switching Outputs | 3 |
| Switching Output Voltage Drop | < 0.8 V |
| PNP Switching Output/Switching Current | 200 mA |
| Valve or Motor Output/Switching Current | 200 mA |
| Short Circuit Protection | yes |
| Reverse Polarity Protection | yes |
| Overload Protection | yes |
| Logic | yes |
| Single Discharge | yes |
| Output Magnetic Valve/Engine | yes |
| Automatic Roller Shutdown | yes |
| Protection Class | III |
| Mechanical Data | |
|---|---|
| Setting Method | Potentiometer |
| Housing Material | Plastic |
| Full Encapsulation | yes |
| Degree of Protection | IP65 |
| Connection | M12 × 1; 4-pin |
| Cable length (L) | 1.5 m |
| Weight | 243 g |
| Output | |
|---|---|
| PNP NC | yes |
| Standards and certificates |
|---|
| Connection Diagram |
|---|
| Dimensioned Picture |
|---|
| Dimensions specified in mm (1 mm = 0.03937")1 = Time Delay |
| Complementary Products |
|---|
|