These sensors have scratch-resistant optics and the emitted light can be switched off. They use the transit time measurement principle to measure the distance between the sensor and the object.
wenglor interference-free technology (wintec) has revolutionized sensor technology:
It makes it possible to mount several sensors directly next to, or opposite each other without the sensors influencing each other. The sensors reach a very high switching frequency and use laser class 1, which is safe for the human eye.
Graphical display for easy operation
Analog output (0...10 V/4...20 mA)
Secure detection of black objects also in extremely inclined positions with wintec
Reliable in case of glossy objects with wintec
2 mutually independent switching outputs
Optical Data
Working Range
50 ... 3,050 mm
Measuring Range
3,000 mm
Reproducibility maximum
1 mm
Linearity Deviation (200…3050 mm)
7 mm
Linearity Deviation (50…200 mm)
15 mm
Switching Hysteresis
3 ... 20 mm
Light Source
Laser (red)
Wavelength
660 nm
Service Life (T = +25 °C)
100,000 h
Laser Class (EN 60825-1)
1
Max. Ambient Light
10,000 Lux
Beam Divergence
< 2 mrad
Reflector required
no
Electrical Data
Supply Voltage
18 ... 30 V DC
Current Consumption (Ub = 24 V)
< 70 mA
Switching Frequency
250 Hz
Measuring Rate
1 ... 500 /s
On-/Off-Delay
0 ... 10,000 ms
Temperature Drift
< 0.4 mm/K
Temperature Range
-40 ... 50 °C
Number of Switching Outputs
2
Switching Output Voltage Drop
< 2.5 V
Switching Output/Switching Current
100 mA
Analog Output
4...20 mA
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Overload Protection
yes
Teach Mode
HT, VT, FT, TP
Interface
IO-Link V1.1
Protection Class
III
Mechanical Data
Setting Method
Menu (OLED)
Housing Material
Plastic, ABSPlastic, PC
Optic Cover
Plastic, PMMA
Degree of Protection
IP68
Connection
M12 × 1; 4-pin
Functions
Off-DelayOn-Delay
Weight
43 g
Safety-relevant Data
MTTFd (EN ISO 13849-1)
349.73 a
Output
Error Output
yes
Analog Output
yes
External teach-in input
yes
IO-Link
yes
Adjustable parameters
Analog output
0...10 V4...20 mA
Output
Analog OutputError OutputPush-pullNPNPNPContamination Output
Other parameters
Off-delayScale analog outputOn-delayFilterHysteresisEmitted lightTeach mode
All other parameters can be found in the product documentation.
Standards and certificates
Display brightness may decrease with age. This does not result in any impairment of the sensor function.