These miniature sensors determine distance between the sensor and the object by means of transit time measurement.
wenglor's interference-free technology (wintec) is revolutionizing sensor technology: it prevents numerous sensors arranged directly opposite or next to each other from interfering with one another. The sensors reach a very high switching frequency and use laser class 1, which is safe for the human eye.
Secure detection of black objects also in extremely inclined positions with wintec
No mutual interference with wintec
Interference-free towards gloss in the background with wintec
Reliable in case of glossy objects with wintec
Miniature design
2 mutually independent switching outputs
Optical Data
Working Range
0 ... 1,000 mm
Setting Range
100 ... 1,000 mm
Switching Hysteresis
< 20 mm
Light Source
Laser (red)
Wavelength
680 nm
Service Life (T = +25 °C)
100,000 h
Laser Class (EN 60825-1)
1
Beam Divergence
< 16 mrad
Max. Ambient Light
10,000 Lux
Light Spot Diameter
see Table 1
Triple Dot Laser
yes
Reflector required
no
Electrical Data
Supply Voltage
10 ... 30 V DC
Supply Voltage with IO-Link
18 ... 30 V DC
Current Consumption (Ub = 24 V)
< 30 mA
Switching Frequency
500 Hz
Response Time
1 ms
Temperature Drift (-10 °C < Tu ≤ 50 °C)
< 2 %
Temperature Drift (-40 °C < Tu ≤ 50 °C)
< 3 %
Temperature Range
-40 ... 50 °C
Number of Switching Outputs
2
Switching Output Voltage Drop
< 2.5 V
Switching Output/Switching Current
100 mA
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Overload Protection
yes
Interface
IO-Link V1.1
Protection Class
III
FDA Accession Number
1620293-001
Mechanical Data
Setting Method
Teach-In
Housing Material
Plastic, ABS/PCPlastic, PC
Cable Jacket Material
Plastic, PUR
Optic Cover
Plastic, PMMA
Degree of Protection
IP67
Connection
M8 × 1; 4-pin
Cable length (L)
200 mm
Weight
15 g
Safety-relevant Data
MTTFd (EN ISO 13849-1)
1,021.76 a
Output
NPN NO
yes
IO-Link
yes
Adjustable parameters
Circuit
NCNOinactiveError outputNC+NO
Other parameters
Off-delayOn-delayHysteresisEmitted lightTeach modeSwitching point