Wenglor

Wenglor P1NH706, Reflex Sensor with Background Suppression

Wenglor P1NH706, Reflex Sensor with Background Suppression

Regular price €579,13
Regular price Sale price €579,13
Sale Sold out
Taxes included.

📦 Ready for dispatch: 19.11.2025

SKU: SKU:P1NH706

The reflex sensor with background suppression works with laser light according to the angle measurement principle and is designed to detect objects against any background. The sensor always has the same switching distance, regardless of the color, shape and surface of the objects. Thanks to the fine laser beam, even small parts can be reliably detected. The IO-Link interface can be used to configure reflex sensors (PNP/NPN, NC/NO) and to output switching statuses.

  • Condition monitoring
  • IO-Link 1.1
  • Laser class 1
  • Recognition of small parts
Optical Data
Range 300 mm
Setting Range 65 ... 300 mm
Switching Hysteresis < 1 %
Light Source Laser (red)
Wavelength 655 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 10,000 Lux
Light Spot Diameter see Table 1
Electrical Data
Supply Voltage 10 ... 30 V DC
Supply Voltage with IO-Link 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 15 mA
Switching Frequency 1,000 Hz
Switching Frequency (interference-free mode) 500 Hz
Response time (interference-free mode) 1 ms
Response Time 0.5 ms
Temperature Drift < 2 %
Temperature Range -25 ... 60 °C
Switching Output Voltage Drop < 2 V
Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
Protection Class III
Mechanical Data
Setting Method Single-turn
Housing Material Plastic, ABS/PC
Degree of Protection IP67IP68
Connection M12 × 1; 4-pin
Optic Cover Plastic, PMMA
Weight 29 g
Safety-relevant Data
MTTFd (EN ISO 13849-1) 2,096.76 a
Output
NPN NC, NPN NO yes
IO-Link yes
Adjustable parameters
Output Push-pullNPNPNP
Circuit NCNOinactiveError outputNC+NO
Other parameters Off-delayOn-delayMode of operationHysteresisSwitching pointEmitted light
All other parameters can be found in the product documentation.
Standards and certificates
Table 1
Detection Range 65 mm 150 mm 300 mm
Light Spot Diameter 3 mm 2,5 mm 1,5 mm
Connection Diagram
Switching Distance Deviation
Typical characteristic curve based on white, 90 % remissionSr = Switching DistancedSr = Switching Distance Changeblack 6 % remissiongrey 18 % remission
Ctrl. Panel
05 = Switching Distance Adjuster30 = Switching Status/Contamination Warning68 = Power LED
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")1 = Transmitter Diode2 = Receiver DiodeScrew M4 = 0.5 Nm
Complementary Products
  • Dust Extraction Tube STAUBTUBUS-03
  • IO-Link Master
  • Set Protective Housing Z1NS001
  • Software
View full details