The sensors function in accordance with the principle of transit time measurement with laser class 1. wintec with Dynamic Sensitivity technology (DS) enables previously unattainable reception sensitivity even with very weak signals. As a result, the sensors have a large working range of up to 10 m and can reliably detect dark or shiny objects even at extreme angles. wintec also works very reliably in adverse ambient conditions, such as those caused by ambient light or contamination. Extensive condition monitoring functions also enable predictive maintenance and trouble-free operation.
Analog output: 4…20 mA
Wide working range and precise detection thanks to DS technology
No interactive influence
Intuitive operating concept
Optical Data
Working Range
0 ... 10,000 mm
Measuring Range
50 ... 10,000 mm
Reproducibility maximum
3 mm*
Linearity Deviation
10 mm*
Light Source
Laser (red)
Wavelength
660 nm
Service Life (T = +25 °C)
100,000 h
Laser Class (EN 60825-1)
1
Beam Divergence
< 2 mrad
Max. Ambient Light
100,000 Lux
Light Spot Diameter
see Table 1
Reflector required
no
Electrical Data
Supply Voltage
18 ... 30 V DC
Current Consumption (Ub = 24 V)
< 40 mA
Measuring Rate
100 /s*
Measuring Rate (max.)
500 /s*
Temperature Drift
< 0.4 mm/K
Temperature Range
-40 ... 50 °C
Analog Output
4...20 mA
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Overload Protection
yes
Interface
IO-Link V1.1
IO-Link transmission speed
COM3
Protection Class
III
FDA Accession Number
2110079-001
Mechanical Data
Setting Method
Teach-In
Housing Material
Plastic, ABS
Optic Cover
Plastic, PMMA
Degree of Protection
IP67IP68
Connection
M12 × 1; 5-pin
Weight
41 g
Safety-relevant Data
MTTFd (EN ISO 13849-1)
512.61 a
Output
Error Output
yes
Analog Output
yes
IO-Link
yes
Adjustable parameters
Output
Error OutputWarning output
Other parameters
Off-delayOn-delaySensitivityFilterUnit of measureMeasuring modeEmitted lightSensor localizationKey illuminationTeach mode
All other parameters can be found in the product documentation.
Standards and certificates
* Depends on mode, see table 2
Table 1
Working Distance
0 m
5 m
10 m
Light Spot Diameter
5 mm
10 mm
15 mm
Table 2