The retro-reflex sensor for transparent objects works with red light and a reflector. It has an IO-Link interface with a data storage function as well as additional configuration and diagnostic options. The dynamic readjustment of the switching threshold function automatically adjusts this for contamination, aging or temperature deviations, meaning that these factors have almost no effect on functionality. The robust V4A (1.4404/316L) stainless steel housing is resistant to oils and coolants, as well as cleaning agent.
Condition monitoring
Dynamic readjustment of the switching threshold
Special for glass, PET and films
High-end
Robust stainless steel housing with IP69K
Optical Data
Range
2,000 mm
Reference Reflector/Reflector Foil
RQ100BA
Clear Glass Recognition
yes
Smallest Recognizable Part
see Table 2
Switching Hysteresis
< 5 %
Light Source
Red Light
Polarization Filter
yes
Service Life (T = +25 °C)
100,000 h
Max. Ambient Light
10,000 Lux
Light Spot Diameter
see Table 1
Single-Lens Optic
yes
Electrical Data
Supply Voltage
10 ... 30 V DC
Supply Voltage with IO-Link
18 ... 30 V DC
Current Consumption (Ub = 24 V)
< 20 mA
Switching Frequency
1,000 Hz
Switching frequency (speed mode)
2,000 Hz
Response Time
0.5 ms
Response time (speed mode)
0.25 ms
Temperature Drift
< 5 %
Temperature Range
-40 ... 60 °C
Switching Output Voltage Drop
< 2 V
Switching Output/Switching Current
100 mA
Residual Current Switching Output
< 50 µA
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Overload Protection
yes
Lockable
yes
Teach Mode
NT, MT
Interface
IO-Link V1.1
Data Storage
yes
Protection Class
III
Mechanical Data
Setting Method
Teach-In
Housing Material
Stainless steel, V4A (1.4404 / 316L)
Degree of Protection
IP68IP69K
Connection
M8 × 1; 4-pin
Optic Cover
Plastic, PMMA
Ecolab
yes
Weight
42 g
Safety-relevant Data
MTTFd (EN ISO 13849-1)
2,175.32 a
Output
IO-Link
yes
NPN NC, NPN NO
yes
Adjustable parameters
Output
Push-pullNPNPNP
Circuit
NCNONC/NO
Other parameters
Off-delayOn-delayMode of operationHysteresisDynamic readjustmentSwitching point
All other parameters can be found in the product documentation.