These sensors function in accordance with the principle of transit time measurement with laser class 1. wintec with Dynamic Sensitivity technology (DS) enables previously unattainable reception sensitivity even with very weak signals. As a result, the sensors have a large working range of up to 10 m and can reliably detect dark or shiny objects even at extreme angles. wintec also works very reliably in adverse ambient conditions, such as those caused by ambient light or contamination. The robust 316L stainless steel housing (1.4404/V4A ) is resistant to oils, coolants, and cleaning agents.
2 mutually independent switching outputs
Robust stainless steel housing with IP69K
Wide working range and precise detection thanks to DS technology
No interactive influence
Optical Data
Working Range
0 ... 10,000 mm
Setting Range
50 ... 10,000 mm
Reproducibility maximum
3 mm*
Linearity Deviation
10 mm*
Switching Hysteresis
< 15 mm
Light Source
Laser (red)
Wavelength
660 nm
Service Life (T = +25 °C)
100,000 h
Laser Class (EN 60825-1)
1
Beam Divergence
< 2 mrad
Max. Ambient Light
100,000 Lux
Light Spot Diameter
see Table 1
Reflector required
no
Electrical Data
Supply Voltage
18 ... 30 V DC
Current Consumption (Ub = 24 V)
< 35 mA
Switching Frequency
50 Hz*
Switching Frequency (max.)
250 Hz*
Response Time
15 ms *
Response Time (min.)
4.7 ms *
Temperature Drift
< 0.4 mm/K
Temperature Range
-40 ... 55 °C
Number of Switching Outputs
2
Switching Output Voltage Drop
< 2.5 V
Switching Output/Switching Current
100 mA
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Overload Protection
yes
Interface
IO-Link V1.1
IO-Link transmission speed
COM3
Protection Class
III
FDA Accession Number
2110079-001
Mechanical Data
Setting Method
Teach-In
Housing Material
Stainless steel, V4A (1.4404 / 316L)
Optic Cover
Plastic, PMMA
Degree of Protection
IP68IP69K
Connection
M12 × 1; 5-pin
Ecolab
yes
FDA compliant
yes
Weight
182 g
Safety-relevant Data
MTTFd (EN ISO 13849-1)
543.71 a
Output
PNP NO
yes
IO-Link
yes
Acceleration sensor
yes
Adjustable parameters
Output
Error OutputPush-pullNPNWarning output
Circuit
NCNC/NONO
Other parameters
Off-delayOn-delayAcceleration sensorSensitivityFilterUnit of measureMeasuring modeEmitted lightSensor localizationTeach mode
All other parameters can be found in the product documentation.
Standards and certificates
* Depends on mode, see table 2
Table 1
Working Distance
0 m
5 m
10 m
Light Spot Diameter
5 mm
10 mm
15 mm
Table 2
Connection Diagram
- = supply voltage 0 V+ = supply voltage +E/A1 = programmable input/output / IO-LinkE/A2 = programmable input/outputE3 = input