The safety light curtain can be flexibly integrated into systems thanks to the well-conceived mounting technology and the compact housing. Alignment of the emitter and the receiver is simplified by the visible red light and the signal strength display. User-friendly wTeach2 software make settings and diagnosis via the IO-Link interface extremely easy. Settings can be subsequently saved to a microSD card and quickly duplicated on other products. Extensive muting functions guarantee an ideal solution for every application in order to safely transport objects into and out of the danger zone.

  • Simple configuration and diagnosis with wTeach2 software
  • Higher levels of safety and availability thanks to intelligent muting functions
  • Multifunctional thanks to measuring function
  • Quick duplication of settings via microSD memory card
Optical Data
Range 0.25 ... 20 m
Housing Length (L) 258 mm
Safety Field Height (SFH) 159 mm
Resolution 30 mm
Light Source Red Light
Wavelength 630 nm
Opening Angle ± 2.5 °
Electrical Data
Sensor Type Emitter
Supply Voltage 19.2 ... 28.8 V DC
Current Consumption (Ub = 24 V) ≤ 100 mA
Response Time 8.2 ms
Temperature Range -30 ... 55 °C
Storage temperature -30 ... 70 °C
Number of safety outputs (OSSDs) 2
Safety Output Voltage Drop ≤ 2.3 V
PNP Safety Output/Switching Current ≤ 300 mA
Number of Signal Outputs 1
Signal Output Voltage Drop ≤ 2.5 V
Signal Output/Switching Current ≤ 100 mA
Short Circuit Protection yes
Overload Protection yes
Interface IO-Link V1.1
Protection Class III
Mechanical Data
Housing Material Aluminum, anodised
Optic Cover Plastic, PC
Degree of Protection IP65IP67
Connection M12 × 1; 5-pin
Weight 420 g
Safety-relevant Data
ESPE Type (EN 61496) 4
Performance Level (EN ISO 13849-1) Cat. 4 PL e
PFHD = 1.8 × 10-8
Mission Time TM (EN ISO 13849-1) 20 a
Safety Integrity Level (EN 61508) SIL 3
Safety Integrity Level (EN 62061) SILCL 3
Function
Hand Protection yes
Standards and certificates
Connection Diagram
Ctrl. Panel
03 = Error Indicator68 = Power LED8a = coding95 = Diagnosis/Large Detection Range
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")
Complementary Products
  • Protection column with Z2SU001 deflection mirror
  • Protection columns with/without protective screen (Z2SS001/ Z2SM001)
  • Deflection mirror Z0030