The safety light curtain can be flexibly integrated into systems thanks to the intelligent mounting technology and the compact housing. Alignment of the emitter and the receiver is simplified by the visible red light and the signal strength display. The user-friendly wTeach2 software makes settings and diagnosis via the IO-Link interface extremely easy. Settings can be subsequently saved to a microSD card and quickly duplicated on other products. Extensive blanking and muting functions ensure an ideal solution for every application in order to safely transport objects into and out of the danger zone.
Simple configuration and diagnosis with wTeach2 software
Higher levels of safety and availability thanks to intelligent muting functions
Multifunctional thanks to measuring function
Quick duplication of settings via microSD memory card
Optical Data
Range
0.25 ... 20 m
Housing Length (L)
709 mm
Safety Field Height (SFH)
610 mm
Resolution
30 mm
Light Source
Red Light
Max. Ambient Light
10,000 Lux
Opening Angle
± 2.5 °
Electrical Data
Sensor Type
Receiver
Supply Voltage
19.2 ... 28.8 V DC
Current Consumption (Ub = 24 V)
≤ 350 mA
Response Time
10.8 ms
Response time (special)
15.7 ms
Temperature Range
-30 ... 55 °C
Storage temperature
-30 ... 70 °C
Number of safety outputs (OSSDs)
2
Safety Output Voltage Drop
≤ 2.3 V
PNP Safety Output/Switching Current
≤ 300 mA
Number of Signal Outputs
1
Signal Output Voltage Drop
< 2.5 V
Signal Output/Switching Current
< 100 mA
Short Circuit Protection
yes
Overload Protection
yes
Interface
IO-Link V1.1
Protection Class
III
Mechanical Data
Housing Material
Aluminum, anodised
Optic Cover
Plastic, PC
Degree of Protection
IP65IP67
Connection
M12 × 1; 8-pin
Weight
1,290 g
Safety-relevant Data
ESPE Type (EN 61496)
4
Performance Level (EN ISO 13849-1)
Cat. 4 PL e
PFHD
= 1.8 × 10-8
Mission Time TM (EN ISO 13849-1)
20 a
Safety Integrity Level (EN 61508)
SIL 3
Safety Integrity Level (EN 62061)
SILCL 3
General Data
Scope of delivery
ZEFX001 mounting
Function
Hand Protection
yes
Scope of functions
Muting and blanking
Output
IO-Link
yes
Standards and certificates
Connection Diagram
Ctrl. Panel
03 = Error Indicator20 = Enter key22 = Up key23 = Down key52 = OSSD ON53 = OSSD OFF60 = display82 = Acknowledgement Request9a = weak signal