Wenglor
Regular price
€337,96
Regular price
Sale price
€337,96
Unit price
/
per
Sale
Sold out
Taxes included.
📦 Ready for dispatch: 02.12.2025
Couldn't load pickup availability
SKU: SKU:SS2-00VA000R2
The analysis module is used to monitor up to 4 through-beam sensors. Interruption of one or more beams results in deactivation of the safety output.
- Please note: According to Machinery Directive 2006/42/EC, this article may only be used as a spare part.
- Four through-beam sensors can be connected
- Potential-free safety relay outputs
- Monitoring of external safety relays
| Electrical Data |
| Supply Voltage |
24 V DC |
| Current Consumption (Ub = 24 V) |
< 260 mA |
| Response Time |
< 80 ms |
| Temperature Range |
0 ... 55 °C |
| Safety Output |
Relay |
| Number of safety outputs (OSSDs) |
2 |
| Switching Output Voltage Drop |
< 3 V |
| PNP Switching Output/Switching Current |
< 100 mA |
| Relay Output/Switching Current (250 VAC) |
2 A |
| Reverse Polarity Protection |
yes |
| Protection Class |
II |
| Mechanical Data |
| Housing Material |
Plastic, PA |
| Degree of Protection |
IP20 |
| Connection |
Screw Clamp |
| Weight |
186 g |
| Safety-relevant Data |
| Safety Category (EN ISO 13849-1) |
2 |
| Performance Level (EN ISO 13849-1) |
PL c |
| PFHD |
3,16 × E-7 1/h * |
| Safety Integrity Level (EN 62061) |
SILCL 1 |
| Function |
| Restart Inhibit |
yes |
| Contactor Monitoring |
yes |
| Standards and certificates |
|
* PFHD for control incl. 4 SL2
| Ctrl. Panel |
| 71 = Channel 172 = Channel 2/Error Indicator73 = OSSD/Diagnosis |
| Dimensioned Picture |
| Dimensions specified in mm (1 mm = 0.03937") |
| Complementary Products |
- SL2-00Nx000H2 through-beam sensor
- Software
|
View full details