Wenglor

Wenglor Y1TA100MHT88, Laser Distance Sensor Time of Flight

Wenglor Y1TA100MHT88, Laser Distance Sensor Time of Flight

Regular price €1.445,45
Regular price Sale price €1.445,45
Sale Sold out
Taxes included.

📦 Ready for dispatch: 03.12.2025

SKU: SKU:Y1TA100MHT88

These sensors have scratch-resistant optics and the emitted light can be switched off. They use the transit time measurement principle to measure the distance between the sensor and the object. For this reason, the object's color, shape and surface characteristics have practically no influence on measurement results. Even dark objects can be reliably recognized.

  • Analog output (0...10 V/4...20 mA)
  • Graphical display for easy operation
  • Emitted light disengageable
  • Temperature drift eliminable
Optical Data
Working Range 0.1 ... 10.1 m
Measuring Range 10 m
Resolution 1 ... 12 mm
Linearity (Working Range 0.1…5 m) 0.05 %
Linearity (Working Range 5…10.1 m) 0.2 %
Switching Hysteresis 3 ... 20 mm
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 2
Max. Ambient Light 10,000 Lux
Beam Divergence < 2 mrad
Light Spot Diameter see Table 1
Reflector required no
Electrical Data
Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 100 mA
Switching Frequency 50 Hz
Measuring Rate 1 ... 100 /s
On-/Off-Delay 0 ... 10,000 ms
Temperature Drift (-10 °C < Tu < 50 °C) < 0.2 mm/K
Temperature Drift (Tu 50 °C) < 0.4 mm/K
Temperature Range -25 ... 60 °C
Number of Switching Outputs 1
Switching Output Voltage Drop < 2.5 V
Switching Output/Switching Current 200 mA
Analog Output 0...10 V
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface RS-232
Protection Class III
FDA Accession Number 0710891-002
Mechanical Data
Setting Method Menu (OLED)
Housing Material Plastic, ABSPlastic, PC
Optic Cover Plastic, PMMA
Degree of Protection IP68
Connection M12 × 1; 8-pin
Functions Off-DelayOn-Delay
Weight 84 g
Safety-relevant Data
MTTFd (EN ISO 13849-1) 345.73 a
Output
Error Output yes
PNP NO yes
Analog Output yes
RS-232 Interface yes
External teach-in input yes
Adjustable parameters
Analog output 0...10 V4...20 mA
Output Analog OutputError OutputPush-pullNPN
All other parameters can be found in the product documentation.
Standards and certificates
Display brightness may decrease with age. This does not result in any impairment of the sensor function.
Table 1
Working Distance 0 m 10 m
Light Spot Diameter 5 mm < 20 mm
Connection Diagram
Ctrl. Panel
21 = Mode Button60 = display
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")1 = Transmitter Diode2 = Receiver DiodeScrew M4 = 0.5 Nm
Complementary Products
  • IO-Link converter
  • Analog Evaluation Unit AW02
  • Fieldbus Gateway ZAGxxxN01, EPGG001
  • Interface Cable S232W3
  • Set Protective Housing ZST-NN-02
  • Software