These sensors can measure distances and display analog output. Their high resolution and wide variety of measuring ranges allow them to be used in innumerable applications. The output signal is practically independent of the object's color.
Resolution up to 2 µm
Linearity: 0,5 %
Measuring range: 10 mm
Optical Data
Working Range
43 ... 53 mm
Measuring Distance
48 mm
Measuring Range
10 mm
Resolution
4 µm
Linearity
0.5 %
Linearity Deviation
50 µm
Light Source
Laser (red)
Wavelength
655 nm
Service Life (T = +25 °C)
100,000 h
Laser Class (EN 60825-1)
2
Max. Ambient Light
10,000 Lux
Light Spot Diameter
0.5 mm
Electrical Data
Supply Voltage
18 ... 30 V DC
Current Consumption (Ub = 24 V)
< 30 mA
Cut-Off Frequency
100 Hz
Response Time
5 ms
Temperature Drift (Tu 40 °C)
5 µm/K
Temperature Drift (10 °C < Tu < 40 °C)
5 µm/K
Temperature Range
-10 ... 60 °C
Error Output Voltage Drop
< 2.5 V
PNP Error Output/Switching Current
200 mA
Analog Output
0...10 V
Short Circuit Protection
yes
Reverse Polarity Protection
yes
Overload Protection
yes
Protection Class
III
Mechanical Data
Housing Material
Plastic, PBT
Optic Cover
Glass
Full Encapsulation
yes
Degree of Protection
IP67
Connection
M12 × 1; 8-pin
Weight
90 g
Output
Error Output
yes
Analog Output
yes
Standards and certificates
Connection Diagram
Error of Measurement
Typical characteristic curve based on white, 90 % remissionSr = Switching DistancedSr = Switching Distance Changeblack 6 % remissionAluminum
Ctrl. Panel
03 = Error Indicator12 = Analog Output Indicator
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")1 = Transmitter Diode2 = Receiver DiodeScrew M4 = 1 Nm